stopped cooling,the compressor would come on and shut back off.
pull the fridge out away from the wall and hope you have a long flex water supply hose.remove cardboard cover,oh yea unplug fridge first.unplug wire from the relay.flip the wire retainer off the relay and pry it away from the compressor.pull the 2 prong capacitor off and then reverse the steps to reasemble. skip the middle man at the local appliance shop.i waited 2 weeks for him to get the part and gave up.your reg shipping got it here in 2 days.
Parts Used:
Relay and Overload Combination
  • william from shady dale, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice water valve leaking
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Parts Used:
Single Outlet Water Valve Kit
  • Byron from Steamboat Springs, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace defrost heater
unplug refrigerator. remove contents from freezer. remove shelves, trays, icebucket, light cover & bulb. defrost back panel w/hair dryer. remove screws from: ice dispenser motor housing, back cover. remove back cover. defrost evaporator w/hair dryer. remove heater leads from connector on feedthru. remove heater mounting screws. pull leads down thru evaporator while removing heaters. install new heaters on mounting plates. feed leads up thru evaporator. connect to feedthru. install everything else.

part was exact fit. same resistance as on schematic, leads were long enough. no problems encountered.
Parts Used:
Defrost Heater - 500W 115V
  • PAUL from BOLINGBROOK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge stopped working
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
Parts Used:
Run Capacitor
  • Dan from Sumner, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water in icemaker tray.
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no water was getting through. Replacing the valve was a snap.
Parts Used:
Single Outlet Water Valve Kit
  • Robert from Myrtle Beach, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer section would work OK but the refrigerator stopped cooling
Tips from internet forums helped me figure out the problem: The defroster heaters were not working and the freezer side would frost up and prevent cold air from entering the refrigerator side. I removed the drawers, drawer slides, ice maker, then the back panel to expose the cooling coils. You can check the heaters for continuity before rempving them by disconnecting the two lead wiresonce you have the back panel removed. Not getting any continuity, I removed the old heaters after defrosting the coils. Removing the heaters was the most difficult part as they are a little "long" for where they fit, but with care it can be done, the same applies to installing the new heaters. I had to cut the connecting wire on one of the heaters to remove it, but got the new set installed OK. Works fine now, the bottom heater was defective, and since the are wired in series neither one will work independently. Everything works fine now, problem solved.
Parts Used:
Defrost Heater - 500W 115V
  • Kenneth from Laingsburg, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker has been working flawlessly since the repair.
Parts Used:
Single Outlet Water Valve Kit
  • paul from madison, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water pump for ice maker would not shut off
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Parts Used:
Single Outlet Water Valve Kit
  • Lawrence from Clio, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost heater shorted out.
Unplugged refrig., emptied freezer, removed ice bucket drive, removed back wall of freezer, used blower side of vac to defrost coils, remvoed glass heaters and pulled a chase line thru as I removed old wires. Replaced heaters and chased new wires using chase wires.
Parts Used:
Defrost Heater - 500W 115V
  • William from Bay City, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Parts Used:
Capacitor
  • Jorge from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!