Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
support clip broken.
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
Parts Used:
Freezer Shelf Support
  • Arturo from Killeen, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer and fridg would not hold the temp correctly. Getting too warm
I had Sears comre and check it out. They wanted $188. for the part and wanted $211 to put it in. They had the part in the truck. The fridg is a GE Profile and only 2 years old. Told them to forget it. Took me literally less than 10 minutes. They did a diagnostics, cost me $77. they told me the problem. I ordered the part here. It came in 3 days and the directions included were awesome. straight forward. Nice to know there is a place to go to avoid getting the shaft from appliance giants. Thank You !

The details: removed the 3 screws, took a picture of the board, didn't need it, unplugged the 6 plugs. pushed 3 clipds holding the board, unscrewed the ground, removed the board, lined up the 3 clips and snapped the new board in place, replugged the plugs and screwed in the ground. Plug the fridg in, done. Literally that easy.
Parts Used:
Main Electronic Control Board
  • Paul from Troy, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Parts Used:
SWITCH LIGHT FZ
  • James from Goshen, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer thawing then re-freezing
The refrigerator was staying in defrost too long allowing the temperature to rise to the point that part of the ice (probably some of the food too) to melt then re-freeze. I first changed out the temp sensor and thermostat because I wanted to try the cheap stuff first but that didn't fix it, I should have gone with the mainboard first as it was the most likely cause. After putting in the new mainboard in the thing has worked perfectly since. The board was extremely easy to change, take the metal cover off with a nut driver. Carefully unplug the wires from old board and remove the board. The board is mounted on some plastic standoffs that expand after passing through the board, some of these came out while i was disconnecting the wires but some were there to stay until I figured out that I needed to squeeze the top of them to release the board. After getting the old board out just put the new one on the standoffs and connect the wires. Put the cover back on and DONE!

NOTES: The new board had some extra connectors that my old one did not, but the correct connectors were still in the old locations. The instructions that came with the board did talk about making some modifications to the refrigerator wiring on certain models, but that didn't apply to me. If I remember right the models requiring modification were all bottom freezer type. But even if you do have to do this the instrucions looked easy, just cut a couple of wires, no splicing or anything.
Parts Used:
Main Electronic Control Board
  • Luther from Navarre, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motherboard burned out
I ordered the part on Sunday and had it by Tuesday. It only took a few minutes to install. Basically, I unplugged the unit and removed the cover over the motherboard with a nutdriver. The wires were easy to unplug and reinstall. There was no way to incorrectly install since they could only fit in the correct position. I reinstalled the panel pluged it back in and now the fridge is working great.
Parts Used:
Main Electronic Control Board
  • Joe from Redlands, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It would freeze up and then it would not cool.
First I unplugged the refrigerator, then I had to open up the back of the freezer, use the hair dryer to defrost the ice that had built up in it. Then I unscrewed the screws on both ends of the existing heater unplugged the old heater and plugged in the new one. Then with the sensor, I cut and stripped the 2 wires attached to the old sensor 1 inch away from the sensor. Then I spliced it with the wires on the new sensor, applied wire nut and black tape tightly. Then I put it all back together.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • Ronnie from Scottsville, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would have ice blockage and eventually both sides would quit cooling. Starting with the refriidgerator side then the freezer side temp would eventually begin to rise all over the course of 2 to 3 days.
Unplugged the refrigerator and removed inside back panel from the freezer compartment and left doors open to allow all ice to thaw. I chose not to use a hair dryer and speed up the process as this could possibly cause more damage if not done with caution. After all ice was melted i took both screws from heat element assembly and followed the simple instructions that came with the new part. Since meters an i dont really work well together and since defrost thermostat and temp sensor were so inexpensive. I opted to purchase those as well in my initial order. They were as simple to replace as a lightbulb. Unscrew the wire nuts from existing sensors and screw wire nuts back on to the new sensors. Buy purchasing all three items at once i felt it just ensured the fiz was complete and the unit has been operating for 7 days like new. One thing i would pass on. If it is the heating element that is burned out, the glass tuve on mine was very black and charred looking. Also when you take it out of the assembly the element was actually in two pieces. Did something cause the element to stay on until it burned out or just old age i dont know. Again, for less than 20 bucks i purchased the additional parts that would seem most obvious to replace and i would recommebd the same. Part select saved us a lot of money not only in parts but in allowing someone with no considerable knowledge in this areato make repairs without hiring an expensive repairman.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat Temperature Sensor
  • Russ from Bella Vista, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
Parts Used:
Evaporator Thermistor Clip
  • roy from spring hill, KS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
Light Bulb - 40W
  • Leo from TWIN FALLS, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
15 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost heater burned out. Lots of ice in and ont he evaporator. Both breezer and refrigerator do not cool right.
Disconnected power. Removed evaporator cover in freezer. Removed the bad defrost heater. It is a glass tube about 10" long. The tube was black since the internal heater wire burned out. Use a hair dryer to melt ice in evaporator. Since there was excessive water coming from melt ice, I removed the back panel and took out the white plastic drain tube and collected water from the tube in a bucket. I put everything back and used the refrigerator for three days without problem, before the new heater arrived. Then I put on the new tube and everything was fine so far.
Parts Used:
Defrost Heater Harness Kit
  • xiaopeng from canton, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It started out with the door buttons not working and then the timer stopped working so it wouldn't allow the fan or the compressor to run replaced the board and everything started working
Took the three screws out of the cover, took the six plugs off of the board and removed board.
Parts Used:
Main Electronic Control Board
  • Robert from Yulee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
Light Switch
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Factory "Single" Defrost Element Was Burned Out.
Unplugged frig. Emptied freezer shelves of food, removed ice container, removed all shelves, removed light bulb cover and light bulb, removed rear panel over coils (2 phillips on bottom and 2 1/4" hex on top/staggered. Used hair dryer hung on a wire to defrost the "ice block" over the coils. Used heavy towels to catch the water in the bottom so the condensate drain didn't just overflow. Removed the 2 screws holding the old element. Unplugged the quick disconnects. The new 2 element heater purchased at partselect is not "encapsulated" like a florescent tube as was the original. Much greater efficiency with exposed element coils. Re-routed blue wire on left of coil bank to the right-used the same split insulator that pink wire is in to keep it safe, did not need to use the jumper extention that comes with the kit. Plugged in both the blue and pink wire quick disconnects, installed the new defrost element with the 2 screws. Cut the old thermostat right up against it's sensor pot. Stripped existing wires, used my own wire nuts to mate the new thermostat, wrapped tight with electrical tape, then tucked them up underneath. Snapped the new sensor on the evaporator line at original location. Replaced panel, plugged frig back in, turned control in frig side to 1, and it works like new now. No more freezer burn. Ice cubes better. Still, this design is poor and no more ge major appliances for me.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • William from Cape Canaveral, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
Parts Used:
Main Electronic Control Board
  • David from Boca Raton, FL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GSS20DBMCWW