Water leaked constantly from water dispenser in door

  • Customer: John from Dexter MO
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 16 of 18 people found this instruction helpful
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.

Fan was noisy and finally quit. Top of freezer was 50, bottom of freezer was freezing.

  • Customer: Richard from Pretty Prairie KS
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 17 of 21 people found this instruction helpful
First I removed the top shelf, ice drawer and second shelf. Next, I used a 1/4" socket and removed the three screws holding the ice maker lower unit, unpluged and removed from unit. I removed the light cover revealing two screws. I then removed the plastic unit holding the fan. I unpluged all plugs and uncliped the white sensor from the back coils. Once the fan was out, I replaced it with the new one by unbolting the fan bracket and putting the new one in place. I clipped the new sensor in place and replaced all the parts in reverse order. I saved $200 in repair costs thanks to PartSelect.com.

Pieces broke off Auger and Cover cracked.

  • Customer: Larry from Georgetown TX
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers
  • 15 of 16 people found this instruction helpful
Remove and empty ice maker from freezer . Remove two screws from bottom to remove the front panel (cover bucket). Remove one screw which holds the deflector on top of the bucket.(tray which holds the ice curbs). Remove one screw that holds the clip that holds the wire actuator rod.

To remove the the ice crusher/dispenser mechanism from the bucket I used two table knives Spread one side of the bucket with one knofe and pry up with the other to get the retainer wedge free from the bucket side. Repeat on the other side. Once the retainer wedges are free the ice crusher/dispenser with the auger attached can be lifted free from the bucket.

With a spanner wrench remove the nylon nut from the shaft. NOTE: THIS IS A LEFT HAND NUT. Note the orientation and relationship of the crusher blades. They must be replaced properly for the system to crush ice and dispense cubes correctly. Remove blades and spacers from Auger.

Reassemble in reverse order. Be sure to get the actuator rod in place in the cam for the dispensor cover before sliding the crusher/dispenser mechanism totally in place. If not in the cam correctly the crusher/dispenser may have to be removed again.

Although a little difficult the first time the project is easily done by an adventourous handy person.

Ice & Ice Cream would melt and refreeze

  • Customer: Joe from Suffolk VA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 15 of 16 people found this instruction helpful
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.

Ice maker quit making ice

  • Customer: Jeffrey from Bluefield WV
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 16 of 20 people found this instruction helpful
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.

Freezer and fresh food section getting warm due to inside coils frosting over.

  • Customer: John from Windham NH
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Pliers, Screw drivers, Socket set
  • 16 of 21 people found this instruction helpful
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.

The compartment behind control panel with snow

  • Customer: Victor from Houston TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 14 of 16 people found this instruction helpful
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.

Solenoid had become rusted/crank door wouldn't close

  • Customer: William M from Ft Myers FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 14 of 17 people found this instruction helpful
First, had to use punch tool to pop out electronic face panel. Face unit still connnect via wires. Use painters tape to hold against refrig. Next, Remove ice/water dispenser and also tape to door. This will give you access to solenoid. Remove the 3 screws holding it in place and unplug fsolenoid from Face Panel. Screw new solenoid and place and connnect to Panel. Goood idea is to unplug regrig. while doing this and put a little WD-30 on shaft of solenoid. May want to order new screws, could be rusty, that hold solenoid in place. Sounds a bit complicated but not that bad a job. You'll save over$100 over GE's service.

Replace broken ice funnel dispenser cradle

  • Customer: David from Sparks NV
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 21 of 38 people found this instruction helpful
Removed outer trim by pulling it carefully out of its clips. Then disengaged the electronic display card by grabing the bottom of the card to disengage the card from the upper clips. I leaned the card forward and disconnected the wire connectors. Removed the 4 screws to take off the frame that contains the funnel. Remove the broken funnel from clips. Note study how the spring is engaged. Note position of the rubber funnel how there is a gap for the water tube. Removed the rubber funnel and attached to new funnel dispenser. Start at one end of the rubber flap and work around engaging the rubber into tabs. Replace the Funnel dispenser back into frame. Make sure the longer wire of the spring sits flat on the plastic frame and that the right elbow of the spring raps around the edge of the funnel. Secured the frame assembly back into the Refig using 4 screws and attached out trim starting withe bottom tabs engaged first.

Noticed pieces of broken plastic in my ice cubes.

  • Customer: G from Spring Hill FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 12 of 12 people found this instruction helpful
Of course, the first thing I did was remove the ice cube container from the freezer, and dump the ice cubes. (Conservation note: If you're in a place with water conservation rules, dump the cubes in a big pot and save them. If they melt, use the water for your house plants.) Following the advice from another DIYer, I let the container warm up before doing anything further.
Turned the container (I'll call it the "tray" from now on) over, removed the two screws holding the front cover with the Phillips screwdriver, gently pulled the cover out to disengage it from the rest of the machine.
Getting the next part out was tricky because it didn't want to release just by pushing in on the tabs on either side of the front assembly. That's where the two table knives came in, courtesy another reviewer. Be careful here not to jam or twist too energetically because the plastic housing is still quite breakable.
Just to be safe, I unscrewed one more screw that held the little bracket holding the rod with the spring on it and disengaged it. Then I discovered that I had to unclip the part that holds the auger in the front part of the assembly and slide the auger out of the way so I could pull the broken part out.
Having done all that, putting the new part in and reassembling the whole thing was pretty easy.
Slide the new part in, carefully rotate the auger back into its place, slide that assembly back into place, replace the clip holding the end of the auger, be sure the long rod engages the ice crusher gizmo, replace the screw that holds the rod in place, hook the front of the drawer back into the proper slots, rotate the cover back into position and replace and tighten the two screws.
You're done! The ice cubes you took out will probably still be frozen, so you can dump them back into the tray and slide the tray back into the freezer.
If you're cleverer than I am, maybe you won't need to do all the little things I did, but even so the whole exercise took less than 15 minutes--the ice cubes didn't even melt!

Main circuit board wouldn't allow the compressor to come on

  • Customer: Leonard from Keller TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 14 of 18 people found this instruction helpful
Removed old circuit board and replaced with new

GE Profile Refrigerator Plug for Water Filter

  • Customer: Linda from Liberty NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 13 of 15 people found this instruction helpful
Called partselect and gave my model number for the frig. I wanted a filter plug because we did not need a frig filter. We have a whole house filter. They looked up the part, took my info, and sent it to me by UPS. It arrived fairly quickly and fit the frig perfectly. I screwed it into place immediately. It was the simplest order I have ever placed and the salesman was very pleasant and proficient. If I have more issues with my frig, I will call partselect again. Just remember to turn off the water before you start.

Iced up Freezer compartment in SxS

  • Customer: Jamison from Heltonville IN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 13 of 16 people found this instruction helpful
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!

The refrigirator light would not come on.

  • Customer: Jania from Novato CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 13 of 16 people found this instruction helpful
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.

the cheap plastic drawer holders broke!

  • Customer: MARYT from KISSIMMEE FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 12 of 14 people found this instruction helpful
Not only were the parts delivered in 2 days....but a phillips head screw driver and matching up the new rails with the old ones turned out to be a super easy and fast repair!! A monkey could do this repair!! But now I noticed the left hand top drawer rail is cracked! It stinks that the quality of the original parts are so poor...but at least I'm saving some money doing it myself!!!