Water inlet valve failed and leaked.
Turn off water supply to dishwasher. Turn off electrical power to dishwasher. Remove lower front cover to expose underneath the unit. Locate the valve toward the left, front underneath the washer. unplug the wire harness from the valve. lay a towel under the valve to catch water that WILL come out. Using a pair of needle nose pliers, squeeze and slide back the hose clamp holding the hose to the water bottle. Remove the 2 screws that mount the valve bracket to the frame. There is plenty of slack in the braided water feed hose to pull the valve out from under the washer. Remove the hose from the fitting and then remove the fitting from the valve. Re-wrap the threads of the fitting with teflon tape and install into new valve. Attach and tighten the braided supply hose to the fitting. Install the valve in reverse order of removal. It takes about 10 minutes to do.
Parts Used:
Water Inlet Valve - 120V 60Hz
  • Bradley from Pine Grove, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)