Tub was filling up with water slowly when washing machine was off
Turn the water supply off. Disconnected the hot and cold hoses from wahing machine. Unplugged the machine from power supply. Removed two screws holding the water inlet valve to the machine frame.
Took the old valve out and marked the wire connectors. Removed the wire connectors and the remaining hose from the old valve. Took the new valve and connected the wires paying attention to the markings made earlier. Uses the little adapter hose which came with the new valve to make the new hose connection on the outlet side of the valve. Put everything back and it worked fine.
These partselect guys are very prompt in sending the things you order. I have used them many times and am very happy to deal with these guys.
Parts Used:
Water Inlet Valve
  • abraham from argyle, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The washing machine would fill up with water when it was not in use.
I turned the water off, detached the hoses and unscrewed the water inlet valve. I unhocked the wires and reattached the wires in the correct sequence on the water inlet valve. Done in 15 minutes.
Parts Used:
Water Inlet Valve
  • MARK from ENGLEWOOD, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey water shut-off after fill cycles
I unscrewed the bottom two front phillip screws. Lifted the front panel at a right angle then popped off downward. Used a 3/8 socket to unscrew the two screws inside in the upfront corners holding the top to the sides. Pulled off the top bleach line.
Lifted the lid upward until it rested on the back wall. Unscrewed the water fill tube connected to the top side panel which to reach the inlet valve area. wrote down which color of the four wires went where. Unscrewed the back plate and disconnected the valve wires. Reversed procedure for installation. Cleaned other parts while I was in there. Installation went quick and smooth.
Parts Used:
Hose Clamp Water Inlet Valve
  • Brian from Ashburn, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No cold water -- only hot
My washing machine would only run hot water. Told my husband and we were ready to call the repair man when I suggested we try to order a part. So I Googled "washing machine repair". Clicked on the first sight I saw and 'searched 'no cold water' amd immediately saw explanation of our exact problem. The solution explained that MOST of the time the problem was the water inlet valve. So I ordered the part. My husband put the part on the machine and the process would have taken less than 10 minutes however the clamp was so rusted to broke and that required a trip to the hardware store. But I suppose clamp-life does not exceed 20 years. So mission accomplished and a great big thanks to all those who explained what they did to solve the problem!
Parts Used:
Water Inlet Valve
  • Darla from Loves Park, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water barely coming in.
First thing I had to determine what was wrong. The machine had worked admirably for a 1980 model but over the last few years cold water input had reduced to almost nothing. There was also a slight hum during filling but it had been so gradual I really didn't recognize it as part of the problem.
After checking that the cold water faucet, hose and screens were okay I removed the front panel to see how water flowed inside the machine. I suspected the inlet valve on the machine was not working correctly so I looked on PartsSelect and found similar repair stories. I ordered one and it arrived in 2 days.
Repair was simple. Turn off hot and cold water and disconnect hoses from machine. Mine were on snug so it took pliers to get a turn started. Lay them in a pan to catch drippings. On the back remove the single nut above the inlet valve and lift to remove the panel. Remove the two mounting screws for the inlet valve. If needed rotate the electrical connections on the new inlet valve to match the old and transfer the wires. Remove the small output waterline and transfer it to the new valve. Mount the new valve to the panel and resecure the panel to the machine. Snugly attach the hot and cold water lines. Turn on the water and after checking for leaks you're good to go.
Parts Used:
Water Inlet Valve
  • Kathy from Priest River, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Slow fill cycle - Hot water barely ran into tub during fill
First I unplugged the power cord from the wall. Then I turned off the water supply shut-offs at the wall and removed the hot & cold connections at the rear of the washer. Then I removed the two screws that held the assembly in the rear of the washer. I then pulled the assembly out about 3-inches, marked the new assembly to show the proper color of wire for each lug and disconnected the four wires at the lugs. I disconnected the rubber fill hose from the assembly and removed the assembly. Next, I installed the new assembly in the reverse order. It worked fine without any leaks & saved me from buying a new washer. My old washer now gets my clothes cleaner than it has for years - much quieter and quicker too.
Parts Used:
Water Inlet Valve
  • Charles from Thousand Oaks, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Letting to much water in.
Turn water off, removed water hoses. removed plug from elec. outlet.Then remove water inlet valve.very simple.
Parts Used:
Water Inlet Valve
  • Harold from CLERMONT, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The washer wasn´t loading the cold water when starting to wash, and that was affecting the whole running cycle
The replacement of the Water Inlet Valve supplied by PartSelect (model PS60378) was too easy.
The key issue was to remove previously the whole upper cover of the washer machine, including the Control Panel, and disconnect all the cables from the electronic Control Board, in order to work easy and freely to remove the inner water hose that is connected to the water inlet valve, working from inside and not from outside of the machine.
Care must be taken writing a notepad of the position of every cable, for not making mistakes when reconnecting them to the Control Panel.
Parts Used:
Water Inlet Valve
  • Pedro from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slow filling - both hot and cold
My Maytag A308 is about 25 yrs old and has been filling by a trickle for a while - both hot and cold. I replaced the water valve and that fixed the hot. Cold still running slow. I switched the hoses, thinking one might be clogged, and determined that the cold shut-off was clogged. I replaced that with a ball-valve - about $10 - and it works like it used to. My advice to anyone who installs a shut-off to any fixture - sink, toilet, w-machine, etc - NOT to use a cheap washer-type valve - they tend to freeze up over time and do not close when needed. Same for clean-out drain on hot water heaters.

Water valve on the A308 was accessible and easy to replace. Required rotation of solenoids was easy and connections were obvious. PartSelect
pictures were very useful and price was better than other on-line sources.

Ron
Parts Used:
Water Inlet Valve
  • Ron from Madison, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Washer filling up with water when idle
I removed the two hoses connected to the valve, then I removed the front panel by removing two screws on the bottom. I disconnected a drum hose connected to the top, tilted the top back, then separated the inlet valve from its metal housing by removing the screws holding it in place. I then removed the metal housing in order to have more access to the old valve. At this point, the valve was only held in place by a few wires. I noted which wires connected where and how the valve was oriented (Hot/Cold position), then removed the wire connections with pliers by grasping the connectors (not the wires). I then reversed this process to install the new valve.
Parts Used:
Water Inlet Valve
  • Tina from The Plains, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
overflow
removed cover, disconnected small water tube and disconnected electrical connections. Reversed above to install new piece. two nutdrivers required. Channel locks for supply hoses.
Parts Used:
Water Inlet Valve
  • Robert from Belleville, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflow
The repair itself is fairly simple. However, being 65 years old getting the new valve back into the back opening of the washer and screwed in was a challenge. The clamp on the water connector hose broke and I had to drive to the store to replace it. You may want to consider giving a heads-ups option of ordering hose clamps to DIYers, when you go to order. Also, the instructions that came with the part was not totally accurate. I had to rotate the cylinders outward to connect to the electrical points. But, my machine is pretty old and that may be why. Otherwise, I am very pleased with how quick I received the part and it was exactly what I ordered. My washing machine is back in business. Thank you
Parts Used:
Water Inlet Valve
  • Ellen from WILLITS, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water keep entering the tub, I had to shut off the supply line.
I order a water inlet valve from this site It was the best buy around. The email from the site part came with a video how to change it. It was a 15 minute job. One 5/16 nut driver to remove the inlet valve and pliers to remove the hoes from the valve. Easy off easy on.
Parts Used:
Water Inlet Valve
  • Kenneth from CARLISLE, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fill stream on my 20 plus year old Maytag washer had slowed to a trickle. The hot water flow was fine, but the cold water flow was a trickle and there was a whining/groaning noise when the tub water was filling. We decided from reading other repair stories on your site that our washer had a mal
We turned off the water, removed the hot and cold water hoses from the machine, then unscrewed the metal plate on the back of our washer that was covering the water inlet valve. Next we removed the output hose and pulled out the inlet valve. As we unhooked each electrical wire we immediatley hooked it to the same location on the new inlet valve. Then we rehooked the out put hose and reversed our steps to finish the job. Before putting the plate cover back over the inlet valve we filled the machine with cold water and ran it through all cycles to make sure we didn't have any leaks. The pictures/insturctions that came with the new part were helpful.

This was the first repair job that our 20 year old Maytag washer has needed, and it was nice to be able to do the job ourselves. Reading other customers's repair stories on your web site helped us diagnose our problem. I found it easy to locate and order the right part and it arrived two days after being ordered.
Parts Used:
Water Inlet Valve
  • Anne from Lexington, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Slow cold water fill; buzzing of inlet solenoid
Other guys have already spelled out in fine detail how to do the actual replacement. What I would add is this: First, I promised I wouldn’t swear during this repair. Second, I got everything I needed together including tools, a small bucket and some old newspaper to soak up the water that is sure to spill. I bought 6 foot stainless steel hoses to replace the old rubber ones. THIS IS HIGHLY RECOMMENDED as the last thing you need is a burst water line. Shorter hoses limit the distance you can move the washer without disconnecting them. The directions were wrong in that I did not need (nor could I use) the plastic sleeve over the outlet tube. So I very carefully had to pry this off without breaking the plastic bushing. And I had bent the clamp securing the outlet hose to the valve, and had a devil of a time getting it back on properly, so you may want to have a small tubing clamp handy as a replacement. Also, I checked for leaks before putting the valve back in place by holding it very carefully, powering up and turning the washer on and off a few times. Keep your fingers and sheet metal away from the terminals or your promise not to swear will be null and void! The last thing is that when I get into a project I go all the way, which meant pulling the washer all the way out and cleaning the floor and all the dust behind it, and even cleaning the washer itself. The result is my Maytag works like new, fills fast without the buzz and looks new, too. I love it when a plan comes together.
Parts Used:
Water Inlet Valve
  • Michael from Beaverdam, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FA4141