No ice
Removed the plate on the back of the refrigerator, removed the bolt holding the water valve in place (didn't know you could cut the water line to get it off), Plugged in the new water valve and water lines, 15 minutes, very easy to do. Removing the ice maker was easy, 2 bolts and a plug. Loosen 2 bolts, lift the ice maker off, unplug it. Put the water chute and ice guard on the new one, put it back on the bolts, spend 1/2 hr getting the plug back in (couldn't see past my own hand), Tighten the bolts and you're done. Really not difficult, except that the plug was angled, and I had to go by feel.
Unplug refrigerator. First I removed 3 screws to remove cover for Board ASM Main located on back of refrigerator then loosen Board by pressing on each of 4 plastic pins then unscrew ground wire (green) then transfer all plugs from old Board to new Board, put back new board through pins, screw back ground wire then put back cover then plug back refrigerator, took 5 minutes
Water would only trickle out at water dispenser, but was making ice.
Since it was making ice I new there was water getting to the water valve on the fridge. I found the water valve on the back of the fridge, put a voltage tester on the water dispenser side of the valve, had someone push in the dispenser flap on the front of the fiidge and found there was 120v. That told me that the switch was good and pretty confident that the valve was bad. Upon reeceiving the replacement valve I removed both electrical leads on the valve remembering witch side goes to which, turned the water line off, removed the water lines, matched them up to the new one, plugged the leads back in on the valve, turned water back on and tested. There will be a little air in the lines, but once that is out the water will flow at a steady stream.
First of all, the larger white plastic tubes in this thing are 5/16" OD, which no plumbing store seems to stock. At the lower left rear end there are 2 tubes, one for water and one for ice, that are doomed to fail being in proximity of a heat source - they essentially get cooked to the point of becoming brittle and cracking. The smaller tube and union can be easily found, but do yourself a favor if the larger one cracks and order the plastic tube and water tube union here, and just cut off the brittle part and amend the old tube using the union.
1. Turn-off water 2. Removed drawers and bottom three shelfs 3. Remove screw inside refrige that is holding the water tank in place 4. Remove bottom front grate on fridge (2 screws) and disconnect water line from quick disconnect (residual water will run out of line) 5. Remove bottom cover on back of fridge 6. Disconnect water line from quick disconnect on bottom left side when looking from the back of the fridge (residual water will run out of line) 7. Remove water tank from inside of fridge 8. Install new water tank - install screw that hold water tank in position 9. Route lines through hole and to the two locations you removed the old ones 10. Install both lines by pushing them all the way in the quick disconnects. Pull on them to make sure they are secure. 11. Turn on water and look for leaks 12. Reinstall bottom front grate (2 screws) 13. Reinstall back cover (5 or 6 screws) 14. Install shelfs and drawers inside fridge
Evaporator motor sounded like wind in the trees howling
I had to remove all of the shelves.....part of the ice maker.....the rear cover over the freezer coils.....There were two wires that came from the back of the freezer that were also incorporated with the fan motor plug from the factory....This caused me to cut all of the wires from the new motor and soider them to the existing plug and shrink wrap the connections. If GE would have supplied two new ends I could have cut only those wires added the ends and inserted them into the new motor plug thus eliminating an extra hour and a soildering iron,,,,In my case not a big deal however not a project for those who have trouble with repairs using these type of tools.
Plastic auger cracked. This part moves the ice in the bin forward to the dispenser
1) Removed the ice bin and emptied the ice. 2) Removed 5 screws total 3) (hardest part) JImmied a flat blade screwdriver into the left top side of the housing and pried gently to disengage the plastic holding clip. This only allows the left side of the housing to move up about a half-inch. Did the same on the right side and 'walked' the assembly out of the bin. 4) Removed the C clip and washer that holds the auger. and removed the auger assembly. 5) Before removing the screw at the end of the assembly, it is a good idea to take pictures of the ice crushing part of the assembly so that it goes back on correctly. 6) Removed the screw and carefully stacked the ice crush blades and washers. 7) Installed the ice crush blades on the new auger, re-installed the screw, washer and C clip. 8) Re-assembly is easy, you just need to set the end of the auger in the back of the ice bin and slowly re-install the housing portion.
freezer defrost and then after some time would work.
one repair man said I needed freon. sears repair man said my evaporators leaked. and should buy a new fridge. I installed the parts for less than $30. dried the freezer compartment removed back panel and asst parts. removed screws from evaporator assy and replaced def therm. soldered leads/wing nuts. removed cover from sensor temp and again connected leads. working fine.
Repeatedly stick in defrost, raising temps in fridge and freezer for hours at a time, some times for days. Repair tech was called out twice to look into this problem, but the temps returned to normal both times before he arrived, therefore, he never could diagnose the problem with a certainity as wh
The main board is easy to get to behind the access plate. You will find seven different wire harness plugs, six which are white, that are impossible to remove without breaking the retaining clips which hold them in place....but that's OK.....you are throwing away the old board anyway, so nothing lost. The plugs will snap back into each of their respective terminal locations without a problem. Be sure to treat the four white, plastic pins that hold the board in place delicately....you will not want to mess those little dudes up!
Ice dispenser quit working and kept making a clicking sound
All you have to do is replace the circuit board which is really easy. Still kinda mad because the fridge is less than 2 years old. If you hear the clicking noise its coming from the circuit board.
This story starts with a GE side-by-side refrigerator that has always had wide temperature swings and a temperamental water dispenser. The ice maker was not making ice, and the built in digital thermometer showed it was running warm. I suspected that the heat exchanger was full of dust and so looked there. What I found was that the condenser tank was hot to the touch and the fan wasn’t running. As an experiment, I aimed a fan at the it for a while I saw that the freezer temperature dropped back to normal. .The fan is marked as 11.2 DC so I checked for voltage at the fan and found some. With three wires and no wiring diagram I wasn’t sure this answered all the questions, but hooking the fan to a 12 volt power supply didn’t get it to spin. I priced parts at a couple websites before using partselect.com . They also have a good diagram to look at (Sears diagrams are really poor). I ordered the part with 2-day shipping; it arrived on time, was correct and fixed the problem.
Well, I first had a local service guy look at the frige. only to find out his opinion was to replace the entire unit, because the Mother board cost more than the unit was worth. Me not accepting that answer, decided to look on line for a part and availability as well as price. Surprise, Part Select had what I wanted. Now, on the back of the unit in the upper left hand corner is the access door for the mother board.Find it, but before proceeding disconnect the power supply from the wall receptacle. Remove the surrounding screws on the access door with a nut driver and the correct size METRIC socket. Disconnect the wiring connectors on both sides of the board. Now there are 4 plastic type (mine were white) retaining studs holding the board in place. BE CAREFUL not to break these as you gently pull the board off studs. Replace board with new one, and restore wire connectors in their perspective places. Each connector has a different amount of pins inside so connecting them is easy. I know nothing about refrigeration, and this was a piece of cake. Less than 15 min. Unit cools like never before!!!
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple. Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use. The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap. After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
The back of my freezer section was covered with ice.
1. Important: First you will need to prepare for water from melted ice. Plug the drain hole in the bottom rear of the freezer. Have plenty of rags near by. A pan or small bucket is helpful.
2. Unplug refrigerator
3. Remove (4) screws (2) w/screwdriver and (2) w/nut driver. You can remove the light cover to get it out of the way but you don't have to.
4. Remove the evaporator cover (The rear wall)
5. Melt and remove any ice build up. Remember those rags?
6. Remove (2) screws from the heater bracket
7. Remove the failed heater. My old heater was a single element. The new heater was a dual element. This made no difference.
8. Disconnect (2) wires.
9. Re-route and reconnect (2) wires. The wires were re-routed because the new heater has both wires on the same side. Not a problem.