Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Refrigerator wasn't "winterized" ..This is a summer home, the cold winter cracked the water valve
I put the new unit up to the old one to see exactly how it goes, took the 2 screws holding the unt off...Took the 3 water lines off with adjustable wrench, put back exactly the same way and it worked with no leaks
I followed the video tutorial published here. The step I altered was setting the shrink wrap; I did not have a heat gun to safely shrink it, so I folded it tightly onto itself and wrapped it in electrical tape. No more frost buildup.
The repair could not be completed. I ordered a thermostat defrost kit but received a collar arbor for a saw. They do not answer the phone at customer service and the order took close to two weeks to get in the first place. Beware of shopping at this site!
During cross country move, water valve froze and broke.
Straight forward repair. Remove the four screws holding cardboard back. Remove the 2 screws holding the valve. Unscrew the water lines and unplug the electrical connections. I would caution that it would be wise to either take a couple photos or write down the order of connection. Even though it is somewhat color coded and the water lines are different sizes, a photo removes any confusion. My old valve had threaded connections using brass nuts and ferrules. The new valve has push in connections so you need to cut the ferrules off.. When cutting off the tubing, be sure to cut square. An angled or "squished" cut will leak when pushed into the fitting. Attach the valve to the refrigerator with 2 screws and replace the cardboard back and you're finished. While you have the back off is a good time to clean the coils. I left my fridge out and back off for a couple of ice making cycles so I could check for leaks (how I know the tubing needs to be cut very square). All in all, a very easy fix.
Removed and replace solenoid manifold valve in rear of appliance using inadequate You Tube video. Removed and replaced augur motor after dismantling various housings using a seriously mistaken You Tube video. The latter video informed us that the yoke that screwed on the motor's shaft was a reversed Left Hand thread. It wasn't at all, and we struggled to figure that out. The people that make these videos leave out steps that they thunk are obvious, but aren't at all.
Well, after watching the video before ordering the part, I ordered the correct part. My wife had ordered the wrong part that I had to return and ordered the correct one. To install the glass you just take out the crisper above shelf and lay the glass in place. So simple.