Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice auger not working to push the ice to the ice dispenser
Easy to remove the auger Motor and Solenoid, however, it didn't fix the problem. $300.00 into it I now have to purchase a circuit board for $382.00. Not a happy camper.
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Removed ice bucket from freezer. Remove ice. Remove 2 phillips head screws from the inside front of ice bucket, and 2 fromt the bottom front to remove the front cover. Remove the E clip and washer from ice crusher shaft. Remove 4, 1/4” head screws from ice crusher housing. Unclip the selector shaft from crusher door paying attention to position.Slide housing off of shaft and discard. Install new housing over shaft and install the 4 screws. Install selector shaft into door. Install the E clip and washer onto shaft. Install front housing with the 4 screws previously removed. Refill bucket with ice and install bucket back into freezing taking care to orient the ice screw shaft into the cog in the back of the freezer as well as the door selection shaft. Test operation.
Did not repair, sensor was not located where you said, wrong sensor was sent to me, can't return oe exchange it COSTERMER SERVICE WILL NOT ANSWER MY EMAILS.
Unscrewed (loosen) screws lifted unit out unplugged electrical connection. plugged in unit hung on screws tightened screws and had ice in less then 1 hour. Rick
Refrigerator wasn't "winterized" ..This is a summer home, the cold winter cracked the water valve
I put the new unit up to the old one to see exactly how it goes, took the 2 screws holding the unt off...Took the 3 water lines off with adjustable wrench, put back exactly the same way and it worked with no leaks
I first ordered the wrong switch I called and got a return label and was refunded my money before even shipping the wrong switch I was helped for the right switch and it arrived in 5 days the replacement works perfectly very easy to install. Thank you