Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Parts Used:
Monitor Door Switch
  • Ernest from RIVERSIDE, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
2 rack holders broke
used the Dremel Osciilating tool with small blade to quickly cut/remove the old rack holder and then inserted new hold. Took less then 5 minutes total.
Parts Used:
Rack Holder
  • Nick from Edison, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light burned out
removed screw that holds glass for light and replaced bulb.
Reinserted screw that holds glass.

Only down side was cost to ship small bulb.
Parts Used:
Halogen Light Bulb - 120V 20W
  • James from Orient, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Charcoil Filter needed to be changed.
GE microwave displayed the message that Charcoil Filter needs to be changed. I disconnected the unit and removed the top two screws then removed the top panel by sliding it gently to the left. Replaced the filter. And positioned it in the same way the old filter was installed. Replaced the top panel and screws, Connected the unit back and used the Menu option to reset the Charcoil Filter warning option.
Parts Used:
Charcoal Filter
  • Kambiz from Mesa, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Rack Holders (Little plastic pieces) Broken
Found your site online, ordered parts needed. When parts arrived I just put them into the holes in the microwave and popped on the self. Worked like a charm! Thanks very much!
Parts Used:
Rack Holder
  • Janice from Summerville, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
6 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Microwave Glass Plate
Odered replacement
Parts Used:
Glass Cooking Tray
  • marielen from newport, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lens Was Not Sized To Fit And Was Left Extremely Sharp
Had to take to a local glass shop for sizing and to remove sharp edges. Will never order again.
Parts Used:
Glass Light Lens
  • robert from salmon, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stove Lights on bottom of microwave burned out and glass cover broke
Just unscrewed the screw holding the cover in place, removed the broken glass wearing gloves and then removed both of the burned out lights. Replaced the bulbs while wearing gloves to avoid the commone problem of contaminating the halogen bulbs during installation which can shorten their life. Replaced glass into cover bent back short tabs to hold the glass in place and closed the cover. Reattached cover with screw and it was done 15 minutes tops
Parts Used:
Halogen Light Bulb - 120V 20W Glass Light Lens
  • Andrew from Park Ridge, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave message "time to replace filter"
It was very easy to remove the old charcoal filter and insert the new charcoal filter(had done it before with with the replacement filter GE had included with the purchase).
Parts Used:
Charcoal Filter
  • Isolde from RIverdale, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Light Socket
Turned the power to the unit off. Removed seven- (7) small screws from the base plate, not removing the rear screws. The plate dropped a few inches allowing me to get to the light socket. I removed one- (1) screw that allowed the socket to be removed. I then detached the two- (2) electrical leads. I now installed the new socket, replacing the leads and the screw along with a new bulb. I pushed the bottom plate back into the up position and replaced the seven- (7) screws. Turned the power back on and we were good to go.
Parts Used:
Light Socket - 250V 75W
  • Richard from Batavia, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
NO light
.Thank You Dan
Parts Used:
Light Bulb - 40W 130V
  • Dan from Leesburg, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable coupler bore became oversized.
Small sized phillips screw driver was required. Once gaining access to the new motor the part(s) replacement was simple.
Parts Used:
Drive Motor Glass Turntable Coupler
  • Walter from Herndon, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen lamps did not light-burned out
Removed the light cover screw with a Phillips screwdriver. Removed the lamps from the packaging just enough to free up the 2 prongs for fitting in the socket. Make sure the power is in the "off position". Install the bulbs one at a time by lining up the 2 sockets (Very important not to touch the halogen bulb glass surface while installing them). Energize the light switch to check operation of the new bulbs.
Parts Used:
Halogen Light Bulb - 120V 20W
  • dennis from harbor springs, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Needed to change filter
Remove two screws on the top of the grill. Slide the grill to the left and then pull straight off. Slide the filter in place. Replace grill and screws
Parts Used:
Charcoal Filter
  • Judy from Friendship, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud noise from the Microwave and the tray was not truning
I followed the directions on your web site. I removed the screws adn dropped the bottom tray, unplugged the drive motor, removed two screw, and replaced with the new motor. It only took about 15 minutes.
Parts Used:
Drive Motor Glass Turntable Coupler
  • LEN from OCEAN SPRINGS, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!