plastic drawer slide was broken
First I watched the video that provided - extremely helpful - thank you- when the part arrived I removed the drawer and shelf - unscrewed the screw- pushed the slide catches to one side and removed - then I screwed new slide on - pushed to lock in the catches and DONE! That simple - EASY PEESEY!! THANKS SO MUCH FOR VIDEO AND SUPER FAST NEXT DAY SERVICE - AMAZING HOW FAST!! WILL USE ANYTIME I NEED PART AND HIGHLY RECOMMEND YOUR SITE! TIME- 5 MINUTES TOPS!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Unplug, remove 2 screws off back panel inside the freezer. Cut wires on old one and crimped in new one. Light to melt the shrink wrap that came with it. Pretty easy.
Can't supply any info that would be helpful. Ordered a " badge" that covered 100% of the scratch and stuck it on. Scratch now covered and problem solved. Thanks for asking.
Turned off fridge circuit breaker Removed all food from freezer and put in cooler. Removed shelves from freezer Removed ice maker Removed 2 hex head screws Tilted back evaporator cover and tried to unplug connection. Found connection was iced over with a huge block of ice coming from water inlet to ice maker Spent several hours trying to melt and chip away ice without damaging fridge. Finally was able to break up ice with long flat head screwdriver and hammer. Unplugged connector and was able to remove evaporator cover. Cut wires near thermostat and removed Stripped wire as needed and crimped new thermostat in place. Used heat gun and lighter to melt heat shrink. This took a long time and required a lot more heat than expected. Reconnected evaporator cover connection and reattached cover. Reinstalled ice maker Reinstalled shelves. Put food back in Turned circuit breaker back on.
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Remove screws from lower hinge and carefully remove the door. In my case it was the lower bearing, flip door upside down being careful to remove anything which might fall off first. I removed the door stop and then pulled the broken bearing out with pliers. Then I pushed the new one in and reassembled it.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
You have sent the wrong part for the THIRD time. You have sent aaccess cover that is TWO INCHES too short. It does not cover the opening, and you will not answer your phones.
There is no way to complete the repair with the wrong part, You have had my order since June 22nd, 2020 and the incorrect part arrived October 27th, 2020. You charged $7.79 plus $1.06 tax and $9.95 shipping. Please refund the entire amount including the shipping, since I did not ask you to ship the incorrect amount.
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.