Models > CTF16ALBL > Instructions

CTF16ALBL Hotpoint Refrigerator - Instructions

All Instructions for the CTF16ALBL
16 - 30 of 247
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Parts Used:
Ice Maker
  • GARY from PARRISH, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
34 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
Parts Used:
Defrost Timer - 120V 60Hz
  • Donald from worthington, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Parts Used:
Ice Maker
  • Gary from Glendale, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Parts Used:
Single Outlet Valve Kit
  • Raymond from Concord Twp., OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Parts Used:
Condenser Fan Motor - 115V
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor rattled loudly
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Robert from Kingwood, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Parts Used:
Ice Bucket - White
  • Tom from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Parts Used:
Single Outlet Valve Kit
  • Kenneth from Bellevue, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I was getting irratic temperture control. I determined that tapping on the control would cause it to turn on or off as it should, on if the frig was to warm, or off if it was to cold.
The temperture control was mounted on the back wall of the refrigerator. One screw and a couple of tabs appeared to be the only attachments. After removing the screw, the freezer control appeared to be an issue since it was also attached to other parts. A little careful pushing revealed that the control knob simply snapped into the cover over the thermastat. Once unsnapped the thermastat and it's plastic cover were only attached by the three electricl connections. Pulling them loose off the terminals left the unit free. Simply examining how the old thermastat was mounted in the cover, and replacing it, and then reinstalling it in the frig was as breeze. All was well again.
Parts Used:
Temperature Control Thermostat
  • Dennis from Kalamazoo, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Parts Used:
Ice Maker
  • debbie from chino hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Parts Used:
Condenser Fan Motor - 115V
  • PERRY from VANDERBILT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CTF16ALBL
16 - 30 of 247