Would not despense ice and getting matal and plastic shavings in Ice when it did despense.

  • Customer: Louie from Lake Park GA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 7 of 11 people found this instruction helpful
Removed screws that held crusher to metal plate, making note of how unit came apart. Replaced Ice bucket auger and front and rear helix. I had to also order bushing/nut that screws to end of auger as the threads on mine were stripped out . I used the parts view on PartSelect.com to help in reassembly of the ice crusher blades, without that view it would have been trial and error in their proper assembly as I had forgotten ( because from 1st parts reciept and second parts reciept being about a week) how they came out. After assembly, with no left over parts I might add, I installed unit in to freezer and it works like new.
Thanks, Louie D.

Cold water for door - leaked on floor

  • Customer: JOSEPH from SURFSIDE FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required:
  • 5 of 5 people found this instruction helpful
Pulled new tubing to the tank and put a union about 8 inches down from tank to new tubing. Great repair. Parts not readily available locally.

stopped making ice

  • Customer: Timothy from Orange Park FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 6 people found this instruction helpful
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.

Door wouldn't stay closed; fridge alarm went off constantly

  • Customer: Ralph from Pagosa Springs CO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 6 of 9 people found this instruction helpful
I removed the door from the fridge by taking off the screws that held the top plate on. I then removed the old broken cam from the door and the old hinge pin on the fridge and replaced them with new parts. I then put the door back on, screwed the top plate of the door into the top of the fridge, and with a few minor alignment adjustments with the freezer door, I was done.

Fan had quit; needed replacement.

  • Customer: John from Divide CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 7 of 12 people found this instruction helpful
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues

Noisy freezer evaporator fan, bearings worn out

  • Customer: Todd from Saint Paul MN
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 5 of 6 people found this instruction helpful
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!

Rails to the bottom crisper were broken

  • Customer: Steven from Sandpoint ID
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 5 of 7 people found this instruction helpful
At first it appeared all was lost since the sales and sevice facility said parts for our GE refrigerator were no longer avalible. We were looking at a $1200 dollar purchase. We decided however to research the internet and see if parts could be obtained. We found Parts Select and to our suprise parts were readily available. We order the drawer side rails and received them within days. The repairs were completed in minutes and for less the twenty bucks.
Steven

broken fan blade in the freezer compartment

  • Customer: John from Cumberland MD
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers
  • 5 of 7 people found this instruction helpful
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.

Replacing the bulb in the freezer side

  • Customer: Yafa (and David) from Bothell WA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.

Quit dispensing and crushing ice.

  • Customer: Charles from Odessa TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 6 of 10 people found this instruction helpful
Ordered new auger and ice bucket assembly. Removed old door and with four screws I attached it to the new unit. Works very well!

Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.

  • Customer: Terry from Simi Valley CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 4 of 4 people found this instruction helpful
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope

I had a smell from the ice and bad taste

  • Customer: Henry from Rockville MD
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 5 of 7 people found this instruction helpful
I removed the 4 screws from the cover and replaced the auger and ice bucket assembly. Extremely simple and I was amazed how easy it was.

Rust on Metal auger leaving rust in ice...

  • Customer: Mike from St. John MO
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 4 of 4 people found this instruction helpful
Disassembled front door/cover (3 screws), then removed deflection door assy, (4 1/4" nuts), CArefully and methodically removed C Clip and grinder teeth...Be careful with this step to document/remeber how to re-assemble! Auger repleced then reverse steps...
All in all, not too bad, but you can easily screw up the teeth re-assembly.

Solenoid controlling the valve had stopped operating.

  • Customer: Eric from Rose Hill KS
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)

All the shelving rails had cracked, vegetable and meat storage bins dropped.

  • Customer: Wayne from Warner Robins GA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
Removed the storage bins, unscrewed the old rails, screwed in the new rails and saved a Sears service call plus their mark up on the parts. Estimated savings was about $100.