Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 6 of 8 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 5 of 6 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.

ice maker chute door not working

  • Customer: DOUGLAS from MILFORD PA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 5 of 6 people found this instruction helpful
removed outside water spill tray and removed exterior cover & interior cover exposing the door arm and solenoid. replaced with new parts including spring. Elontronics have a plug which is easy to disconnecct. & reconnect
old solenoid head would not have fit new door arm
and vice versa.
I strongly suggest using the kit.
A Torx type screw driver is required for all screws
on the Jenn-Air

Refrigerator (Top, non-freezer section) light switch broke & light socket bad with age.

  • Customer: Henry from Clinton Township MI
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 8 of 15 people found this instruction helpful
Turned off power to Refrigerator.
1)Removed broken light switch, using a screwdriver, to gently pry it out. Then unlugged the switch from the connector. I used long nosed pliers to gently pull out the connector from inside the frig, so I could easily plug in the new light switch. I then pressed the new light switch back in place.
2) Remove light cover. I then unclipped the socket which holds the light bulb, I gently pulled it out and unplugged it from the two wires. I then attached the two wires onto the new light socket and clipped it back in place. Bingo done with both items practically no time!

light inside fridge was flickering and clicking

  • Customer: bill from escondido CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 6 of 9 people found this instruction helpful
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok

Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser

  • Customer: Kenneth from Newton Grove NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 5 of 7 people found this instruction helpful
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.

The ice maker stopped making ice.

  • Customer: Thomas from Cupertino CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 4 of 4 people found this instruction helpful
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.

Door closer on refrigerator side was worn out

  • Customer: Robert from Londonderry NH
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 4 of 4 people found this instruction helpful
This was a very simpler repair to an annoying problem. First I removed the decorative cover on the top hinge pin of the door which was held on with one screw. I then removed the 3 screws of the top hinge pin with a socket, held the door in place with my hand and took off the top pin. Next, I simply lifted the refrigerator door off the bottom worn out hinge.
removed the old door hinge bracket and bottom lower hinge pin that had worn, placed the new bottom hinge pin in the bracket. Finally, on the bottom of the refrigerator I replaced the natural door closer held on by one screw. Lifted the door back onto the new bottom hinge pin, held the door in place and installed the top hinge pin, put the cover back on and the refrigerator is closing like it was new again.

Door parts separated, didn't seal or function

  • Customer: Derek from Leslie MO
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers
  • 4 of 4 people found this instruction helpful
Followed the directions included with the parts, which were exact and well illustrated. If you are comfortable working around circuit boards and electrical connectors (with the power OFF, please!), then you can do this repair. Why electronics on this repair? Because you have to unplug a board to get to the parts, and disconnect the connectors to the solenoid. But again, the directions were fabulous, and I'm almost looking forward to needing to use PartSelect again. Almost.

Ice maker eitehr wouldn't make ice, or made odd shaped cubes

  • Customer: J. Bradley from Wellsville NY
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 4 of 4 people found this instruction helpful
First, I shut off the water going to the refrigerator, then removed the ice bin. Then I loosened the two screws on the top of the ice maker (the one toward the front was a little tricky, since you can't see it at all), then removed the screw that fastens the lower bracket to the side of the frig. Then I lifted up on it slightly to remove it from the two upper screws, then unplugged the wiring harness from the side of the refrigerator and lifted the whole unit out of the frig.

I then removed the plastic cover on the front of the ice maker, pressed on the tab to remove the wiring harness from the old ice maker, and installed it on the new ice maker. I then removed the metal arm from the old ice maker and installed it on the new unit as well. The last part that I moved from the old ice maker to the new one was the lower bracket, as the bracket on the new ice maker was bent during shipping.

Once those parts were swapped, I put the plastic cover on the new ice maker, plugged the wiring harness back into the side of the frig, routed the fill tube into the back on the ice maker assembly, and set the unit back on the two upper screws. I then put the screw back in the lower bracket, tightened the two upper screws, and then put the ice bin back in and turned the water back on. After a couple of hours, I threw out the first couple of batches of ice and it is now working as it had in the past.

I also noticed, when looking at the old ice maker, that the black plastic coating was coming off the ice cube tray, so it was a good time to be replacing it anyway. Overall, a very easy job (I was prepared for swearing, parts being slightly off, etc.) and it would have been a shame to have paid someone to do it.

Ice maker just stopped making ice

  • Customer: Thomas from Valencia PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver
  • 4 of 4 people found this instruction helpful
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.

condenser fan stopped working

  • Customer: Steven from Brigham City UT
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.

The round door on my ice chute broke off

  • Customer: Stanley from Avon IN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 4 of 4 people found this instruction helpful
I ordered the ice dispenser and selenoid door kit, it was easy to repair because I only needed the door. As per the instructions I removed about seven screws and disconnected the power source to the dispenser unit, pulled the unit out
and replaced the door in the two slots. Plugged the power source back into the slot, put the screws back in, now it works like new.
Thank you PartSelect, I received the part in just a couple of days. I recommend your service to everyone. I saved myself a lot of money and will order again on any needed
parts in the future.

The plastic ring that is the connection between the drive motor at the back of the freezer compartment to the auger in the ice bin shattered when my wife was dispensing crushed ice.

  • Customer: Larry from Anchorage AK
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
Part selects cataglog for parts selection was very easy to use and the online service and delivery was great.
When I got the part, it was not apparent on how to remove the auger so that I could insert the new connector. There were about about 8 visible screws, with star drive heads that I fortunately had a screwdriver that fit, and I could not tell if I had to remove all of them or only a couple.
I ended up removing all, but still could not separate the dispenser portion which held the front of the auger from the back of the ice bin. I finally figured out that the dispenser door trip lever had to be disconnected and I almost lost it when I removed the metal clip that attached it to the outside of the ice bin when the spring loaded lever tried to unwind. I managed to hold it in place, separate the dispenser holding the auger from the rest of the ice bin and replace the connector. I them got the pieces back in place and was able to refasten the spring loaded lever and then replace the screws.
If the spring loaded lever had unloaded, it would have been tricky to try to replicate the amount of turns (load) on the spring tension.

Icemaker would not fill with water.

  • Customer: Linford from Cedarville NJ
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 5 of 8 people found this instruction helpful
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.