Ice maker over flowing

  • Customer: ben from manhattan KS
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 8 of 9 people found this instruction helpful
My ice maker was overflowing and i realized that it was the water valve that needed replaced. unscrewed 1 nut, unhooked 3 water lines, unhooked electrical components and re-installed in reverse order. took about 10-15 mins.

Ice bucket auger yoke was stripped out and turned freely

  • Customer: James from Pineville LA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 7 people found this instruction helpful
Removed the ice bucket from the freezer. Removed the single screw on the left side with a nut driver, then lift and pull the tray toward you...there is a wiring harness in back of the tray that I had to unplug...easy, pinch the sides of the plastic connector and it disconnects..and the tray came out of the refrigerator...and the cussing started. Since the threaded yoke was stripped it could not be unscrewed from the motor shaft...I took my trusty Dremel Tool and cut the shaft off so the yoke could be separated from the motor shaft and the motor could be removed from the plastic housing. From here on it was a piece of cake...install the new motor and screw the new yoke onto the motor shaft... I think it has a left handed thread, like the old propane bottles used to have..slide the tray back in, reconnect the wiring harness (it only plugs in one way), make sure the tray is sitting on the 4 side supports, put the single screw on the left side and you are done....put the ice bucket back in and flip the bail down and you should be back on business....!!

fan had stopped-freezer not performing etc.

  • Customer: George from Glenwood MN
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!

Condenser fan motor seized

  • Customer: Benjamin from Daytona Beach FL
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.

Door flap not opening correctly and noise when pushing button for water

  • Customer: Charles from Allen TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 7 of 7 people found this instruction helpful
This repair was relatively easy due to the instructions provided and took about 15 minutes. Originally, I had bought a door flap thinking that was the problem (a small plastic piece on the flap had broken off) but after replacing that the assembly still would not allow ice flow. I then purchased the kit including solenoid and the repair worked. I had a bad solenoid all along. My suggestion is to replace the entire kit rather than one part as it is likely all parts need replacement.

Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 8 of 10 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

broken ice door chute

  • Customer: Alexander from Raleigh NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 8 of 11 people found this instruction helpful
first unplug the refrigerator (power) remove the dispenser platform (removable) remove two torx screws, slide the cover up unplug the wire from the cover by sliding the ribbon tape up from the circuit board, remove the three torx screws slide the plastic from the hose (water dispenser hose) unplug the electrical (2) remove the two torx screw from the magnetic relay reassemble the door about 15 minute if you know what you are doing

Broken (froze) ice maker water valve.

  • Customer: richard from Little Suamico WI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 8 of 11 people found this instruction helpful
1. Turn off fridge and Pull plug from wall.
1a. Turn OFF water supply!
2. Remove rear dust cover to gain access to water valve.
3. Mark power connectors(red/green) attached to water valve before removing them. Remove connectors.
4. Remove supply line from old valve.
5. loosen mounting screw holding old valve in place.
6. remove valve.
7. disconnect two plastic water lines from valve.
8. Cut 1/2 inch off the end of each plastic line to get to un-streached line. Make sure you have enough line to still reach valve!
9. Insert plastic lines FIRMLY into outlets of NEW VALVE to lock in place. outlets are different sizes so you can't reverse them!
10. Install new valve and tighten mounting screw.
11. replace/tighten supply line to new valve.
13. Replace dust cover!
14. Plug in, Turn on fridge.
15. Turn on water supply, bleed air out by drawing a glass of water at door, and check for leaks!
All Done!

No ice

  • Customer: Jon from Boise ID
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 8 of 12 people found this instruction helpful
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.

condenser fan stopped working

  • Customer: Steven from Brigham City UT
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 9 people found this instruction helpful
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.

Water line inside freezer would freeze and block flow

  • Customer: Grant from Naples FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 9 people found this instruction helpful
The old valves water lines had threded connectors, I cut those off and pused the line into new valve put everything back together. Only additionalwasto clean ice from around icemaker where hose fills it with water. It'sben working fine for a week so far.

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 7 of 9 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson

noisy fan motor, fridge & freezer not holding temp

  • Customer: Paul from Joshua Tree CA
  • Difficulty: Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 8 of 12 people found this instruction helpful
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder.
I did this for less than the price of a service call by a repair shop.

The threads on the yoke shaft stripped.

  • Customer: Steven from Crossville TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 10 of 19 people found this instruction helpful
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 6 of 7 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.