Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frostfree Amana failing to defrost
First step, call the repair man. He listened, and then said to get a new refrigerator, since this one is 28 years old and the repairs could amount to a significant part of the price to buy new. Even if he fixed this, it could develop other problems, yada. So we went out to buy and discovered nothing suitable that would fit in that slot of our kitchen! We'd need new counter top and cabinets to fix this problem! So we went to the Internet and searched to find the likely source of the problem and the parts schematic at PartsSelect.com. Yah! We ordered the part, and then found we had no idea how to install it. Sooo, back to the Internet, and eventually got some good clues - it goes in the kick space under the front, and just plugs in, once you can get to it by removing the bracket that holds it. Working underneath a refrigerator is not complicated but it's awkward. The form of the new timer was not exactly the same, but it does function correctly. We have no experience whatsoever with appliance repair, so pretty amazed at our success. This old Amana looks very good inside and out and is now working perfectly again. If it lasts a few more years, we will be thrilled to have spent $15 to save $500. We can always buy new later on.
Parts Used:
Defrost Timer Kit - 120V 60Hz
  • Sharon from Champaign, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator had been acting for like a month, it would get cold then for no reason it would just stop working. But the bottom always stayed colder then anything else, so I googled until I found a forum for doing it yourself
I first removed the panel in the bottom so I could see the fan and the Bimetal thermostat. Also removed back panel so I could see the tester wire and make sure I was going to be able to pull it though the small hole. Removed the old thermostat. Clipped new one on made sure I had reconnected all plugs correctly. Turned on refrigerator and waited about 30 minutes to see if fan kicked on and all was good replaced panels. This was totally great for me, I'm a woman and for me this was very exciting for me to be able to fix it myself without having to call in a repair man or just replace the refrigerator.
Parts Used:
Bimetal Defrost Thermostat
  • Tammy from Okeechpbee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor slowing down and speeding up off and on
Unplugged the machine removed the bottom plate and back plate and ice maker.Removed 2 wires to motor and ground wire.Removed 2 mounting nuts for motor,installed new motor and used old fan blade for new motor .Reinstalled in reverse order plugged in and tested fine.
Parts Used:
Evaporator Fan Motor - 60Hz 120V
  • James from Aubrey, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water in icemaker tray.
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no water was getting through. Replacing the valve was a snap.
Parts Used:
Single Outlet Water Valve Kit
  • Robert from Myrtle Beach, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would work ,then heat up melt all ice then freeze the water , temps up and down fridge would be warm ,cold, warm ,cold
took out back panel of freezer compartment , exposed fan and coil thermostat was clipped on to coil, removed ,replaced,each wire one at time , the 2 extra wire that go out back dont go to anything its for factory testing.clipped them off pulled out from back, put wire ties on to keep wires from fan area . closed up . timer is in a metal box under the freezer door pulled off bottom facia 1 screw on metal box remove old timer installed new . everything working great now. no more warm beer
Parts Used:
Bimetal Defrost Thermostat Defrost Timer Kit - 120V 60Hz
  • vincent from Huffman, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer/Fridg warm & middle strip between doors warm
Timer: Removed 2 screws from cover. Removed 2 screws to remove Timer. Installed new Timer & reassembled (15 min).
Thermostat: Removed screws from lower panel in the freezer. Removed thermostat from the cooling coil. Disconnected electrical connections. Had to cut 2 wires coming from fridge & install plastic piece provided. Made up all electrical connections (1 hour).
Parts Used:
Bimetal Defrost Thermostat Defrost Timer Kit - 120V 60Hz
  • Edward from Clinton, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker has been working flawlessly since the repair.
Parts Used:
Single Outlet Water Valve Kit
  • paul from madison, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not coolling properly. Lower temp. 2 degrees upper temp. 60 degrees.
Take bottom racks and baskets out of freezer. Remove back sheet metal panel, 8 screws. Remove motor and bracket, 2 screws. Umplug wires on motor. Remove two more screws to take mounting bracket off motor. Install in reverse order. Simple job. Maybe 20 minutes. Besure to shut freezer off before startin work.
Parts Used:
Evaporator Fan Motor - 60Hz 120V
  • John from Blairsville, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No cooling, compressor not running and was very hot
Plied off the relay switch with a screw driver. I could not pull it off by hand. Disconnected the wires to it and replaced with new part. Had problem getting the part back on and lining up the pins with the connector. I had to line up one pin and start at an angle and roll the part onto the contact pins.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
Parts Used:
Compressor Start Device and Capacitor
  • Miriam from Canyon Country, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge random humming
Unscrewed back of fridge and unplugged relay from compressor and plugged in the new one remember that the new one turns 180 degrees from existing switch.
Parts Used:
Compressor Start Device and Capacitor
  • robert from central point, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!