Ice Dispenser "round chute" broken side tab, ice/water fountain not working

  • Customer: Scott from Walker LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 83 of 87 people found this instruction helpful
I could see that a tab was broken from the round chute that opens for ice dispensing and closes to seal off freezer ice chute when not in use. With the tab broken, the round door would not shut to seal the freezer chute and dispensing water would spatter everywhere. I looked for just the round door part, but is only sold in the "Ice dispenser solenoid and door kit" I only had to use the round chute/flap from the kit. The instructions were easy to follow and I had the fridge back working in about 10 minutes. It took me longer to find the right star headed screwdriver that I needed to remove the Maytag star screws (5) total. Because I didn't have to replace the solenoid or the spring mechanism, this was especially easy, and now I have those parts on hand if one day I need them!!

Ice maker and water dispenser would stick on. Would have to oprn door to stop flow of water or ice

  • Customer: David from Springdale OH
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 59 of 65 people found this instruction helpful
I replaced the actuator switch and rubber pad with the switch actuator.
I had attempted to repair previously without replacing the pad but the problem continued. I put up with the problem for a long time waiting for the opportunity to get to the appliance parts store but their hours are hard to deal with and work myself. I was able to find the part easily with the on-line catalog and parts diagram and ordering was no hassle at all. Shipping was extremely fast.
I remove the front panel by removing the drip tray and the 2 screws at the bottom. Then gently lift up on the front cover assembly (careful with the connector to the circuit board at the top) it slides over 2 screw heads at the top. Remove all the screws that secure the dispenser to the fridge, one screw is hidden on the right side (as you face the front. Work the dispenser out and careful of the water tube coming from the top - it stays in place. The wire connector must be unplugged from the left side in order to remove the assembly and not actuate the dispenser while working (a good idea to unplug the fridge). A small phillips screw holds the switch in place and the actuator fits over with the slots fitting over lugs on the assembly. Reinstall as you removed - be careful to be sure all wires go back into the proper location and "tracks" to keep them out of the way and avoid pinching (if the actuator will not go back flush in its location check the wires to the switch).
Plug all wires bach in and don't forget the harness to the top of the circuit board on the front panel.
Plug back in and check your work.
Important to replace the actuator pad - its "elasticity" is the return mechanism for the switch actuator. Probably the issue I had after replacing the switch and still suffering the same problem.
Good Luck!

Ice Maker had quit due to faulty valve

  • Customer: Brian from Imperial CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 38 of 46 people found this instruction helpful
Repair work was very easy. Water supply was to the icemaker/water dispenser. After removing the outer fiber cover with a screwdriver, the valve was removed by unscrewing one nut. Post removal water lines were removed with a ordinary pair of scissors approximately 1/2" from where it entered the faulty valve. the two electrical connections were then removed from the faulty valve. The water lines were then connected to the replacement water valve very easily by just inserting and applying a small amount of pressure. The electrical connections were then connected, replacement valve reattatched to the frame work (fit perfectly). After this I turned on the water and BINGO ice :) Post knowing the replacement valve worked I re-attached the fiber cover and pushed the refrigerator back in it respective location. Again this repair was very easy and the part arrived sooner than expected.

The part that closes with the solenoid broke off and did not close the ice maker

  • Customer: Karen from Rocky River OH
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 15 of 17 people found this instruction helpful
I removed the two screws that hold the element in place. I then unscrewed the four remaining screws with a star screwdriver and pulled the element out and disconnected the wire. I removed the part containing the solenoid, spring loaded holder and the plastic closer. I did not need to replace the solenoid or the spring loading device only the round circular piece that opens and closes the ice door. I just snapped it into the spring loaded part and replaced everything as I had removed it. It was very simple. Your need the star screwdriver though for removing the screws.

ICE DOOR WOULD NOT OPEN

  • Customer: Stanley from Southlake TX
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 14 of 15 people found this instruction helpful
JENN-AIR JCD-2389GTW REFRIDGERATOR/FREEZER SIDE BY SIDE

ICE DOOR WOULD NOT OPEN TO DISPENSE ICE FROM THE ICE DISPENSOR

I did an online order for the repair kit #PS2003478 (115V) Ice Dispenser Solenoid and Door Kit to fix the problem with the ice door not opening. As I had deduced, the “solenoid” had gone bad, and the kit held most all the items required to make the repair. The only additional item the kit needs to have is the “fountain door return spring”. Be careful not to loose the spring when disassembling the unit. You might want to order an additional spring just in case you loose or break the original.

The instruction sheet was pretty thorough, except for being small and the pictures hard to see. My refrigerator/freezer has decorative panels that had to be removed before I was actually able to get the escutcheon off of the unit, and this configuration wasn’t addressed in the instructions. After figuring out that I had to remove all the trim from the door of the freezer before I could start the repair, the job wasn’t that difficult, but you have to have patience and take your time to make sure you don’t damage the electrical components of the ice dispenser. MAKE SURE YOU NOTE THE POSITION AND LOCATION OF THE FOUNTAIN DOOR RETURN SPRING BEFORE YOU REMOVE THE ICE DOOR!! This is important so that you can get the correct “tension” when reinstalling the mechanism. If there isn’t enough tension on the spring, the door will not seal properly, and the dispenser will freeze up.

Also, when it comes time to disconnect the “electrical edge connector” from the control panel, be sure to make note of it’s position. It isn’t difficult to pull off, but could be easily broken if you are not careful.

The rest of the repair and installation is straight forward and simple. Just take your time and it goes back together pretty easily.

Tools you will need are; Needle nose pliers, Phillips screwdriver with a small and medium bit, and a “TORX” tool set to remove the TORX screws from the escutcheon and fountain bracket.

Ice Maker Wouldn't Fill Consistently

  • Customer: Steven from Northridge CA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Wrench(Adjustable)
  • 11 of 12 people found this instruction helpful
Replaced old dual outlet water valve with new design, which eliminates the (reportedly) troublesome "y" connector. A relatively simple matter of unplugging the refrig., turning off the water that feeds the ice maker and removing the cardboard/fabric service panel at the bottom rear of the refrig. Removed one screw with a nutdriver, disconnected the valve from both lines and out came the old valve with little fanfare. Next, as I replaced the valve with the new and improved version, cut out the "y" connector and used the supplied union and tubing to connect to the existing water line (just upstream from where the "y" connector was). Then, as my water/ice dispenser was sticking "on", I went ahead and replaced the rubber activator and internal switch. This just required moving a few hex screws on the front part of the dispenser to gain access to the parts. A relative snap and now all is working well.

control board shorted out making it inoperative

  • Customer: Stan from Clovis NM
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 14 of 21 people found this instruction helpful
removed ice and water dispenser to get to control board and removed two screws and electrical plug and two other wires and remove c/b then replaced c/b and all wiring and screws put it back togather in appro. 25 to30 mins.

Ice Maker selnoid malfunctioned.

  • Customer: Robert from Kokomo IN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 11 of 13 people found this instruction helpful
I called PartSelect and was greeted by a real live person instead of a recording. The lady was very helpful and kind. We decided on the part that I needed, and it arrived to my home in less time than she said it should. I completed the repair with the instructions provided in just a short time. My experience with PartSelect was positive, and it reminded me of the way businesses used to be. I highly recommend them.

ice dispencer would not stop dispencing

  • Customer: james from emmitsburg MD
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 9 people found this instruction helpful
first i remove the two screws like the guy said on your web site. then i pulled the cover off with a upward motion revealing three more screws witch i removed. I then removed the dispencer. unpluged the wires and removed the switch and pad and replaced with new parts.I reinstalled the wires then the unit, installed the screws and cover.Checked for proper operation.Then enjoyed that cold beer! Thanks to your wed site and repair info. I saved at least 100 buck to the repair man. Thanks Partselect.com

Worn out actuator pad on the water/ice dispenser

  • Customer: JEFF from TALLAHASSEE FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 8 of 8 people found this instruction helpful
First I removed the spill tray, and removed the two screws on the bottom of the dispenser. I was then able to remove the front of the dispenser, which revealed 3 more screws. After removing those screws, the entire assembly lifts out. I removed the old pad, put the replacement pad on, replaced all the screws and the tray, and was done! It took about 10 minutes, start to finish. I saved at least $75 on the repair by doing it myself, and the part only took 3 days to arrive. Best of all, the water and ice dispenser works like new! Thanks, PartSelect!

Ice maker stopped working

  • Customer: Ronald from Chardon OH
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 7 of 7 people found this instruction helpful
Since I had no water in the try I started with the valve first. That did not fix the problem so I replaced the Ice Maker assembly however that still didn't solve my problem. The only thing left was the relay that entergized the valve. The part number shows NLA so I googled the part number on the relay and found one at Mouser Electronics under PN:G2R-1A-T-AC120. The whole project took me several days to solve however the actual time involved was only about 1 hour.

Door flap not opening correctly and noise when pushing button for water

  • Customer: Charles from Allen TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 7 of 7 people found this instruction helpful
This repair was relatively easy due to the instructions provided and took about 15 minutes. Originally, I had bought a door flap thinking that was the problem (a small plastic piece on the flap had broken off) but after replacing that the assembly still would not allow ice flow. I then purchased the kit including solenoid and the repair worked. I had a bad solenoid all along. My suggestion is to replace the entire kit rather than one part as it is likely all parts need replacement.

Broken (froze) ice maker water valve.

  • Customer: richard from Little Suamico WI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench(Adjustable)
  • 8 of 11 people found this instruction helpful
1. Turn off fridge and Pull plug from wall.
1a. Turn OFF water supply!
2. Remove rear dust cover to gain access to water valve.
3. Mark power connectors(red/green) attached to water valve before removing them. Remove connectors.
4. Remove supply line from old valve.
5. loosen mounting screw holding old valve in place.
6. remove valve.
7. disconnect two plastic water lines from valve.
8. Cut 1/2 inch off the end of each plastic line to get to un-streached line. Make sure you have enough line to still reach valve!
9. Insert plastic lines FIRMLY into outlets of NEW VALVE to lock in place. outlets are different sizes so you can't reverse them!
10. Install new valve and tighten mounting screw.
11. replace/tighten supply line to new valve.
13. Replace dust cover!
14. Plug in, Turn on fridge.
15. Turn on water supply, bleed air out by drawing a glass of water at door, and check for leaks!
All Done!

Control board and fountain backet damaged by burned out solenoid.

  • Customer: Wing from Stockton CA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 7 of 9 people found this instruction helpful
Removed damaged fountain bracket by removing the torx screw using torx head screw driver. Install new control board and new solenoid onto the new fountain bracket using existing screws. Reinstall fountain bracket to the freezer door.

Ice chute door won't close tightly

  • Customer: Thomas from San Diego CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 6 of 7 people found this instruction helpful
First unplug AC power from the back of the refrigerator and I then removed entire fountain bracket assy that hold by 3 screws. Pull toward with some angle to able to access to a plug of wires and then disconnect it. Pull fountain assy downward. Set it on work place, remove all screws and transfer wires, switch, ice dispenser controller unit,solenoid, spring, flapper...and then install them to a new fountain bracket. Please note that this problem is 100% relating to mechanism. To test this work: Hold Fountain bracket assy vertically, press a flapper,position "open" and make sure return spring is working properly (enough pressure) . Now, install this unit back to my refrigerator. During installing screws, check flapper that can shut tightly enough and secure all screws, check a flapper again. I got it right for the third time because I was not aware of some parts alignment.