Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Parts Used:
Condenser Fan Motor Kit
  • Barbara from Apollo, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
not cooling could hear a clicking noise
With the help of the website I was able to verify that the part I removed (in the area of the clicking sound) was probably the part required for replacement. I ordered it, installed it... IT WORKS (I knew it the moment I plugged in the power cord and heard the compressor kick on). Saved me from buying a new fridge or calling a repairman. I'm a 58 year old woman with no appliance experience. I watched the videos and installed the part without any trouble. Thank you PartSelect for your easy to use website instructions and helpful hints.
Parts Used:
Defrost Timer
  • Deborah from Elkton, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer was too cold and refrigerator was too warm
After receiving the part, I watched the installation video on the PartSelect website. The step by step demonstration was excellent. I felt confident I could do it myself after watching the video just once, and utilizing the written instructions that came with the part. The installation went smoothly, and my refrigerator is functioning correctly again. Best of all, I did not have to go through the hassle and expense of hiring a repair person!
Parts Used:
Defrost Timer
  • Jolinda from Eau Claire, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Parts Used:
Condenser Fan Motor Kit
  • David from Salem, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
frosted evaperator
I was a Sears repair man for fourty eight years , so I don"t think I should say how easy this was.
Parts Used:
Defrost Timer
  • Burton from Mount ShaSTA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Parts Used:
Condenser Fan Motor Kit
  • George from Hickory, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Both the freezer and bottom of refrig too hot
Was very simple once I found out where the defrost timer was located. I had a friend walking me through trying to find the location on the phone. Not all models have them in the same place. Once the part was located all I had to do was remove the cover, unplug the old one and plug the new one in just the way the old one came off. The black wire was easy to locate on the old and just matched it up. Put the cover back on and plugged it in. It was no time till I started feeling it cool. Checked both top and bottom with thermomater and it was where it should be within 12 hours. I am happy and using it again. Was almost ready to throw it out. Did not know it was so cheap to fix one. Nothing anyone can't handle. If this woman can do it anyone can.
Parts Used:
Defrost Timer
  • Marcia from Kansas, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Parts Used:
Condenser Fan Motor Kit
  • Tom from Paducah, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Parts Used:
Condenser Fan Motor Kit
  • john from thibodaux, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Freezer iced over, water leaking into refridgerator
My fridge is a little different from the video model. The Controls in the fridge are located on an "arm" which swings down when the two screws are removed from the sides. It was not necessary to remove a front plate or knobs. However, I found when I got in to it that the old timer was not held by screws, but by plstic posts which had these "speed nuts" on them. This is a little metal plate which fits over the plastic post and bends to lock it in place. When you try to remove it, it acts like a barb, holding the little sucker on. I ended up bending the ends of those little suckers up tight against the post and twisting and pulling with needle-nose pliers. I broke one post like others before me commented, but one stayed intact. The only break at the top, so there ie still post left to hold the new timer. Once it was off, I was able to replace easily. The directions for choosing the right prong were a little confusing, but follow your gut and go with the wire colors. My schematic found in the bottom of the fridge did not look like any of the drawings, but I could match the wire colors. I also asked "Just Ask" for help, to make sure. My gut instinct was right. My fridge is now working again beautifully. If a housewife with no appliance repair knowledge can do it, so can you. I fixed my dryer with PartSelect too!I will never call another repair man until I have checked this site to see if I can do it myself. Bet I have saved $600 so far at least!
Parts Used:
Defrost Timer
  • Jennifer from Cincinnati, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Parts Used:
Light Bulb - 40W
  • Grant from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Refregirator would not freeze properly. It would stay in the defrost mode at times.
I did the repair just as your video showed me. It worked out great.
Parts Used:
Defrost Timer
  • Eartis from Mckenzie, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
No Light
Took socket out and replace it with new one. Very easy. W saved alot of money doing it ourself.
Parts Used:
Light Socket Kit
  • Mary from Jefferson Township, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The Refrigerator Was Running But Blowing Hot Air, Everything In Freezer Had Defrosted.
First I watched the video on your website, it was quite helpful. It showed me the location of the part to be replaced. Then I used the nut driver to remove a couple of screws, and slowly pulled the cover off . Once I pulled the cover down I could see the part that needed replacing, it had a couple of phillips head screws holding it in place, I removed those screws and unplugged the defrost timer, taking note of the color of the wires. Then I took the new defrost timer and attached the loose wire to the correct terminal according to the directions(this is where the color of your wires comes in), then I plugged in the new defrost timer and replaced the screws. I then reattached the cover making sure not to pinch any of the wires, and replaced the screws. It was so easy I was sure I did something wrong and it wouldn't work, but I plugged the refrigerator back in and let it sit for about 20 minutes and then when I checked it was running cool. I'm 55 years old and never had the nerve to try anything like this before but since my husband passed away I've had to try things myself or replace a lot of appliances. If I can do it anyone can.
Parts Used:
Defrost Timer
  • Jeanne from Fairview Heights, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Parts Used:
Condenser Fan Motor Kit
  • John from LAS CRUCES, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10666660