Freezer and refrigerator would get warm, followed by it getting cold again, doing this numerous times throughout the day.

ApplianceGeneral Electric Refrigerator

Model

Level of DifficultyReally easy

Time to do repairLess than 15 mins

Age of Appliance1 - 4 years

Tools Nutdriver

Anthony From Yardley, PA

Jan 27, 2009

1 out of 1 people found this instruction helpful

After determining it was not a problem with the defrost cycle, ( this refrigerator had no separate defrost timer), I ordered the main circuit board with the hope that the relays built into it were hanging up and not properly turning on the compressor, (a chattering sound could be heard). Ten screws to take the access cover to the board off and a few connectors later and it was as good as new. Took about ten minutes!