M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
Parts Used:
Primary Door Interlock Switch
  • Jeffrey from FULSHEAR, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Parts Used:
Primary Door Interlock Switch
  • johnny from port orange, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken lower glass light reflector
Easy slip in to 2 hinges
Parts Used:
Lower Glass Cover
  • Mark from Newton, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Interlock Switch Failed
Removed cover, diagnosed problem, ordered part from Parts Select, received part in 2 days, replaced part, tested and replaced oven into built in space.
Parts Used:
Primary Door Interlock Switch
  • Michael from Littleton, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
When trying to run, intermittently, the light would come on but the tray wouldn't rotate or cook. When the door was open, the tray would intermittently rotate.
I pulled out the unit and found 2 interlock switches that are depressed when the door closes. After cycling the door open/closed I found that one of the switches occasionally would stay depressed. The repair was easy (after I took off the panels so I could get to the switch) I simply removed 2 screws that attached the interlock switch assemblies to the main unit. Then I popped out the defective switch and popped in the new one. This did indeed fix my problem.
Parts Used:
Primary Door Interlock Switch
  • Sam from Chandler, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
lights were burned
It was REALLY EASY finding the right parts using your diagrams..Thanks for your HELP!!I will definitely be back.Dan H
Parts Used:
Light Bulb
  • Danny from Louisville, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Mica cover protecting waveguide was sparking
The part had to be rotated to fit then screw was replaced. Only tricky thing was that the screw was the security allen type with a small post in the center. Luckily I had a set of them from installing similar bolts on license plates.
Parts Used:
WAVE GUIDE MICA COVER
  • David from Williamsburg, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Could not be turned on
Removed outer cover and then replaced the T. C. O. located on the left upper side if the unit. Replaced outer cover, tested oven. Oven operates normally.
Parts Used:
Oven Cavity Temperature Cut-Out
  • Remer from Dothan, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Microwave would turn on ,BUT turn table would not turn and oven would not heat.
Took off cover , unpluged switches , took off switch assy, off/on test hooped and howlered for about 5 mins .Then laughed about other sites said could get those switches. Just wanted to say I LOVE Partselect. Super fast del , great price. JUST AWSOME!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Parts Used:
Primary Door Interlock Switch
  • Earl from New Philidelphia, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZSC2000FBB02