Models > ZSC2000FBB02

ZSC2000FBB02 General Electric Microwave - Overview

Get Parts and Repair Help for ZSC2000FBB02

If you know the microwave repair part you need, you can browse the list of all parts on the ZSC2000FBB02, or you can search by name or part description. You can also find your part by where it is located on the ZSC2000FBB02 by selecting a section below. If you’re not sure which part you need, you can narrow your search by selecting a common symptom and we’ll show you the repair parts most likely to fix your microwave. Installation instructions provided by other do-it-yourselfers will help guide you through your repair.

Search for parts
Keep searches simple, eg. "belt" or "pump". Need help?

Primary Door Interlock Switch

This interlock switch is located in the door latch.


Drawing Lamp

Also known as Light Bulb. Sold individually. Appliance may take 2.



Also known as rotating ring assembly.


Monitor Switch


Ceramic Cooking Tray

This tray rotates in your microwave ensuring more even temperatures.


Oven Cavity Temperature Cut-Out

Also known as fuse.


Non-Stick Metal Tray/Pan


Shaft - Turn Table





Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Everything seemed to work with the controls, but when you pressed start the light would come on and nothing else. The turntable and heating system would not function.

  • Customer: Keith from Bowling Green KY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 21 of 31 people found this instruction helpful
I unplugged it, removed the outer shell with torque bits and a screwdriver, drained the main capacitor, and began debugging the circuit with my fluke multimeter, found the bad primary interlock, googled the part number, ordered the part, received it in 2 days, replaced the interlock in about 2 minutes, and put the cover back on. Fixed. Saved me about $200 ... read more

Broken shaft -- turn table would not turn.

  • Customer: James from OKLAHOMA CITY OK
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 14 of 15 people found this instruction helpful
Safety TORX driver removed screw. Ceramic cover removed with ease. Shaft pulled straight up and out. Broken piece not retreivable and left in base of oven. New shaft inserted over "D" stub. Ceramic cover replaced and screw tightened.

When the ceramic cover is removed, this allows the glass cover for the UV heating unit to be removed, cleaned,... read more

Microwave runs with the door open

  • Customer: Thomas from Andover NJ
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 14 of 20 people found this instruction helpful
Remove microwave outer cover. Turn on side & locate the upper & lower door switches. Better to replace in pairs even if one is ok. Remove the wire harness to each switch. Then replace switch and re connect the wire harness. Re attach outer cover
and test to see if that solved the problem. If so then well done!! read more