ice maker was spewing water into freezer
Ordered this part after i replaced the plastic tubes on the back as the problem persisted. loosen the nuts holding the water inlet lines, remove the cover to the valve. remove the valve and the water inlet line to the the valve. Disconnect the 2 outlets from the valve. 1 outlet to icemaker and other outlet to water cooler (bigger). Connect water inlet and 2 outlets to the new valve, test the water lines. Found the inlet is leaking, removed it and added teflon tape and reconnect it. All is done. Then I left the freezer door open for 3 hours to melt the ice on the wrong places and all is well.
Parts Used:
Dual Inlet Water Valve
  • andy from clearwater, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Icemaker would only make crushed ice, no cubes
I first replaced the ice bucket which allowed the auger to turn but did not fix the problem. I then ordered a new solenoid and plunger and after installing them it now makes ice cubes. Problem solved.
Parts Used:
Ice Dispenser Bucket Ice Bucket Seal Ice Dispensing Drive Cup
  • John from Snellville, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fridge not cooling
Fairly easy I pull the fridge foward and remove the backing board and notice the fan wasn't working, so I remove the fan and bench tested and it was burned then I clean the condenser with compress air if you don't have air then a vacuum cleaner works then once the part arrived I install it the now if working very good
Parts Used:
Condenser Fan Motor - 115V
  • Pedro from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Plastic Cracked On Water/Icemaker Valve
1. Turn water supply off at wall. Unpulg referigerator. Remove all cardboard backing covering valve. Vaccum under ref. Unscrew water line where it attaches to valve on ref. (Reuse this later) unplug 4 electrical prongs. Mark with colored pen if not already color coded, so can put back correctly. Pull old ice maker and ref water supply out of valve if it does not screw in with nut. Cut very short peice off end of ref water lines. Slide new locks on water supply lines and push into water valve very hard to lock. Cant get them wrong as they are different sizes. Plug in electrical connectors same as you unpluged them. Connect water line to valve from wall. Turn water on and check for leaks. If none. Replace all screws on backing. Recheck for water on floor. If none congrads, just saved yourself about $120. 00 Labor. Take 2 asprin, drink a six pack and go to bed.
Parts Used:
Dual Inlet Water Valve
  • Donald from Reynolds, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?