motor would start by itself when door closed
remove 4 screws from top, front louvered panel snaps out. remove 1 screw from top of keypad, keypad pivot's forward and can be removed. There is a white mounting bracket inside left. Remove two screws, one top and one bottom, bracket lifts up and out. 3 sets wires are attached, mark them with masking tape, top, center, bottom and pull out plugs. They can only attach one way. Using a very small screw tip, lift plastic latch from switch, it rotates out and is removed from the pivot pin. reassemble in reverse order after switches are replaced
Parts Used:
Door Interlock Switch Kit
  • Lewis from Loveland, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins