Our refrigerator would lose its cool.
I found that the evaperator coil was freezing up solid, not allowing air flow. Something was wrong in the defrost circuit. After troubleshooting, I found that the defrost timer was okay, as well as the fan. The only thing left was the temperature switch (thermostat). I found the part online for a reasonable price and ordered it. The part actually came the next day, I was amazed. I removed the old part by cutting the wires. Then I snapped in the new thermostat and crimped the wires back together (color-matched). It was that easy and I saved myself hundreds of dollars. Great service!
Parts Used:
Defrost Thermostat Kit
  • Toby from Barstow, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Too much weight in the crisper and I cracked off ther part that slides into the drawer guides.
I simply needed to replace the drawer. Customer service Really Is Customer Service at this company! The young lady with whom I spoke on the phone was courteous, knowledgeable and efficient. She knew what I neeeded from my rather inept description. I was told the drawer would arrive in 10 to 12 days, but I actually received it in 3!!!!
Parts Used:
Crisper Pan - Large
  • Ursula from Oconomowoc, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller
proped up frig, loosened screws, cut pin, installed rooler w/ new pin, rounded pin end, reistalled, lowered frig...everyone happy, thanks again partselect.
Parts Used:
Roller Pin Single Roller
  • John from Capac, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not self close tightly
Remove two screws from top door hinge.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
Parts Used:
Door Closure Cam Kit
  • paula from julian, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice forming around ice chute
I had to order three times before I got the right part. This was due to my rush to fix the problem and not studing the diagram carefully (black and white diagrams are not that clear). The repair was very simple. Just remove the rubber from the plastic door and slip on the new one.
Parts Used:
Ice Chute Door
  • George from Tunnel Hill, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cam snapped in half on bottom of door
Super easy - emptied door of all food, unscrewed bracket from top of door, lifted door off and set aside. Broken cam removed, new one screwed in, and lubed with some Vaseline. Set door back in new cam, screwed bracket into the top, and good to go. I was kinda worried about shopping from PartSelect since I had never heard about them, but the part was here in less than 2 days. Pretty awesome little company.
Parts Used:
Door Closure Cam Kit
  • Mason from Tallahassee, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close properly
Removed the door by taking 3 screws out of the top and lifting straight up, then replaced with the new parts and very easily replaced the door, worked ike a charm, if i didn't know any better it was like factory new
Parts Used:
Door Closure Cam Kit
  • Sarkis from Havertown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door made a loud noise on opening and closing.
Emptied the door.
Removed the door, top bolts first.
Lifted out the door.
Installed new cam at the bottom.
Set the door back in place.
Bolted the top hinge back on.
Smooth!

The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
Parts Used:
Door Closure Cam Kit
  • Dennis from Kerrville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This is almost embarassing but you asked....
Once the part arrived, which was very quickly BTW..all I had to do was remove the old filter and then just screw the new one into place....Now I just happen to be both female and blonde but was able to get the job done in less than 15 minutes (that includes opening the box) and with very little water dripping from the old filter!!! Looks like I could work as the Maytag repair woman soon!!
Parts Used:
Refrigerator Water Filter
  • laurie from gold canyon, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frezzer kept freexing up, and auto defrost would not work. Fan running, compressor not turing on, fridge warm.
Removed all the food from the freezer. Removed 5 screws that hold the back cover on and removed the cover. Melted the build up of ice that was present on the coils and other components behind the cover. I was sure to keep a towel under the fridge as the drip tray was sure to over fill. With the fridge unplugged, cut the wires from the thermostat. On the wiring side, not the thermostat side, shorted the wires I just cut together and plugged in the fridge. The defrost heater turned on. This told me that it was indeed the termostat and not the timer. Replaced the thermostat and it has been runing ever since.
Parts Used:
Defrost Thermostat Kit
  • Barry from Pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Auger
Wow! less Than 15 mins to install, called partSelect and within two days the Auger arrived and with handy socket it was done!
Parts Used:
Ice Maker Auger and Crusher Blade Assembly
  • Marshall from Marrero, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original drawer slide in component cracked
Pulled out old, slid in new. Presto, change o!
Parts Used:
Crisper Pan - Large
  • Jon from Saint Marys, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slides cracked and broken off in sections
Removed the top glass shelf to make slides easier to reach. Then simply removed the old tray and installed new one. You do have to watch for the small stops in the slides or you could damage new unit.
Parts Used:
Crisper Pan - Large
  • Donald from Helena, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bottom Cam broke on Fridge Door
Removed top hinge cover and socketed out hinge nuts. Lifted door off bottom hinge. Socketed out broken bottom cam and replaced with new. Reset door with someone lifting and the other guiding. Reattached top hinge and cover. Voila.
Parts Used:
Door Closure Cam Kit
  • Jon from Butler, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Chute door broke off and fell to the floor
Unplugged refrigerator.
Removed water drip tray.
Removed two Phillips screws.
used putty knife to
get behind outer plate and popped it off.
Disconnected electrical connections.
Removed the 4 nut driver screws.
removed ice maker door.
Removed seal around old Ice shoot flap and cleaned.
Removed insulator pad from old ice maker flap and cleaned.
Installed seal and insulator pad on the new chute door.
clipped new chute door intact with seal and pad in place and snapped the top clips into place.

Reversed procedure to reinstall refrigerator parts.

Plugged in refrigerator and tested. Had no issues.
Parts Used:
Ice Chute Door
  • Leon from TUSCOLA, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.