everything worked except it wouldnt cook
tested all 3 of the door switche for continuity, the top switch was faulty, replaced it,for approx $4.00 and saved a $350 dollar microwave.
Parts Used:
Switch,Micro
  • Joseph from N VERSAILLES, PA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door sensor switch went bad. Microwave would not operate.
Watched a couple of repair videos on Youtube by searching for the model number. Found out what to do in order not to get shocked by the powerful capacitor.
Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.)
Bought a tamper-proof star bit to get the cover off. Followed the directions to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place.
It's all back together, and the wife is happy!!
Parts Used:
Micro Switch
  • Randall from ARCADIA, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Magnitron failed
Over the stove microwave installed in top cabinet row.
1. Unplug device.
2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet.
3. Remove screws from sheet metal cover.
4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place.
5. Unplug magnetron and remove the 5 screws.
6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3).
7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Parts Used:
Magnetron
  • Joseph from WILTON, NH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light bulb was out
It was a bit awkward because the microwave is mounted over my stove. I had to twist around and install the bulb and then replace the cover. It was a bit uncomfortable. It took me about 10 minutes to complete.
Parts Used:
Light Bulb - 40W
  • Leslie from WILLINGBORO, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed new filter
unscrewed and removed grate. removed old filter and slide new one in.
Parts Used:
FILTER
  • linda from HIGHLAND, IN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace bulb under the microwave
Piece of cake. One screw to release the dropdown light diffuser. Just remember, the you're screwing the new bulb in from a reverse perspective. Also this site sends the correct part the first time.
Parts Used:
Light Bulb - 40W
  • Verne from HENDERSONVLLE, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The over the stove microwave door would not close.
I unplugged the microwave. I did watch a YouTube video to see how the plastic frame around the door could be removed. I used a putty knife to pry it off. The spring was still in good shape, so I hooked it up to the new latch/locker part and onto the microwave. This was just a little time consuming because I was trying to be careful so I wouldn't break anything on the new part. The plastic frame clicked right back on. I plugged the microwave in and it worked right away. If I can do it, you can do it. Sure beat buying a new microwave. Great experience.
Parts Used:
Locker
  • Christine from LUXEMBURG, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light bulb out
Put s pot under were you take the screw out.If you drop it you can get it easy
Parts Used:
Light Bulb - 40W
  • Joe from RAIL RD FLAT, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When the MW door was opened a fan would start running. Close the door the fan would go off.
Removed the MW from the wall. Took the top screws off the air vent. Then removed the two screws holding on the display. I then moved the display to its side and it revealed the micro switches. I removed the plug in leads from the micro switch one at a time. I did this with all three micro switches only one at a time. I reinstalled everything and plugged it in. No more fans starting when the door is opened.
Parts Used:
Switch,Micro Switch,Micro
  • vic from Allen, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door switch was burnt out
Removed outer cover

removed lower door switch

installed new switch

Wa La!
Parts Used:
Switch,Micro
  • Edward from ORCHARD PARK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turn table not turning
My part arrived the next day. That was a surprise to receive it that quick.
I removed the lower panel to gain access to the motor. Disconected the 2 electrical leads and removed the 2 screws that held the motor in position. Installed the new motor, reconnected the leads and reinstalled the lower panel. It was a very easy reapair. I took all of 10 minutes to complete.
I will definately use Parts Select the next time I need a repair part for any appliance.
Great service
Parts Used:
Turntable Motor - 60 Hz.
  • Randy from East Peoria, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turntable erratic and noisy
Removed 6 screws from bottom cover and 2 from motor cover. Unplugged motor and installed new motor. Plugged in new, Installed cover. Done
Parts Used:
Turntable Motor - 60 Hz.
  • michael from montgomery, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights bulbs burned out
Really easy for a 75-year old female; just spent more time reading the online manual than actually installing the light bulbs to find out where to access the light bulbs.
Parts Used:
Light Bulb - 40W
  • Kat from Hudson, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light blew out
change light bulbs
Parts Used:
Light Bulb - 120V 25W
  • KELVIN from SOUTHFIELD, MI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven would not start when closing door.
Removed some cosmetic panels. Removed the assembly with micro switches. Examined the faulty switch by checking the clicking action of switch. Two others were ok by this method. Replaced the switch with new one. Works fine so far. Thanks to web site and YouTube videos.
Parts Used:
Micro Switch
  • Raymond from DEPEW, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!