Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
condenser fan stopped working
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
The old gasket was very misshaped and leaking badly
Start by loosening each of the screws holding the white inner part of the door to the rest of the door under the flap of existing gasket. Do not completely take the screws out or the door will come apart making the job much harder. Once all screws are loose, the gasket should pop out.
To install the new gasket push the beaded edge back into the crack. You may need to loosen the screws a little bit more to push it in. After it's all the way in, tighten all the screws back up. Be sure to make sure the inner part of the door didn't slide down when all the screws where loose. If it did, the door may not close properly. To fix this, lift up the inner door while the screws are loose, hold it in place, and tighten a few of the screws. It also helps to empty the shelves in the door.
One other helpful item. I taped a large piece of cardboard to the fridge while I was working on the door to keep it as cold as possible.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
The plastic wheel broke in half at the right front of the refrigerator.
The good news is that the part (the wheel was available.) I bought two in the event that the other wheel may break in the future. The bad news is that the housing that holds the wheel was riveted together by the wheel axle. It would have been nice to know that before I bought the part and if the housing with the wheel installed was available. The refrigerator was at my summer house a hundred miles away. Anyway, we had to grind the end of the riveted axle to dislodge it from the wheel housing. With the axle dislodged from the housing we were able to install the wheel and then hammer the end of the axle flat to keep in place, like the original rivet installation. It is not perfect but it held and should be fine. I am glad I was able to get the part and will be back in the future, if in need of other parts.
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
remove front grill. with pry bar and wooden block, elevate side with broken wheel and insert wooden block behind assemble from the exterior bottom. With roller wheel assemble lose from the wooden block remove front elevator screw from the front frame. next remove cotter pin with the pliers and pull assemble pin. next elevate assemble out. drill out axle on the crimp side insert from the hardware store one 5/16 x 21/2 bolt with nut and new wheel. reinsert assemble in the reverse order. Remove wooden block and adjust height of wheel. replace grill. job complete. good job