Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The ring was cracked and it would not dispence ice.
I switched the ring and still had the same problem. What caused the Drive ring to crack was the Ice maker drive was cracked also, when it filled with water it would tip. The ice was not freezing completely and would cause the ice to build up and the auger was froze with ice or a big piece of ice would jam it. So I replaced the Ice Tray, it is working like new. I have to buy another ice tray as inventory, although I know inventory is bad but I never agreed with that theory.
Had to cut the old part off with dremel then just install new part and put back in refrigerator. It is a good thing to know that the Yoke is a left threaded. Thanks James from Pineville.
Removed the screws that held the main ice bin and slid back the bin to leave space behind the auger to remove the broken ring. Replaced with new ring and replaced screws to hold ice bin back in place.
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Removed drive assembly end of ice bin using socket wrench to get to old ice bin drive ring. Pull drive sssembly back to get ice bin ring out of the other end of ice bin. Installed new ice bin ring and and reinstall drive assembly end.
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
unplug the refrigator, remove everything from frezer compartment. remove ice maker three screws and un plug. remove rear panel 4 screws remove motor bracket from rear panel 4 screws unplug motor . replace motor and reasemble in reverse order. the new motor is very quiet.