freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
Pantry Drawer Cover keeps falling off, not held in place by End Cap Kit
I removed the 2 crisper drawers and the glass shelf directly above the Pantry Drawer. Removed the Pantry Drawer and Pantry Drawer cover so you have easy access to the Right-Hand End Cap. On the right-hand End Cap, there are 2 screws which hold the End Cap in place, use a 1/4 inch driver to unscrew the screws from the front of the cabinet on the End Cap and half-way in of the cabinet, leave the screws in their holes in the End Cap. Lift gently to get off a small plastic pin, and move the End Cap away from the Cabinet. You don't need to completely pull the End Cap out of the cabinet, it'll move more like a door opening. Place 2 washers on each screw and gently put the End Cap back into place, being careful NOT to jostle too much so the washers don't fall off the screws. You will need to gently lift the End Cap back in to place over the plastic pin. Hand-tighten the screws back into place with the 1/4 in driver. Remount the Pantry Drawer on the sliders. When you go to install the Pantry Drawer Cover, you will need to gently push on one of the pins to get the cover back into place. Put glass and crisper drawers back into place.
Test by gently pulling on the Pantry Drawer. If properly mounted, the pins will extend fully into the Cover and will keep it secure when opening the Pantry Drawer.
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket