Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
When moving the range, the 220 wire popped off the terminal and arced melting the plastic terminal
I looked for a new terminal locally, but no one had s terminal that would fit a 40-year old range. I went on line to PartSelect and could not find my model range, so I looked through all the terminals listed on the website (about 500) but found only one that was close to mine. Mounting holes did not match, but it had 3 connectors with 220 capability, so I ordered it. I requested express shipping by UPS and thought I paid for the extra charge. When I got notification of shipment. I saw it was via ground. It went from Louisville to Jacksonville to Clearwater, FL. I ordered it on Thursday night and received it the following Tuesday night. Meanwhile, we had no stove to cook on. When the part came, it took two days to get the contractor back to our condo. He drilled new holes on the mounting box and jerry-rigged the wiring to make it fit. The range is now working, but I was disappointed in the delay in shipping which I agreed to express shipping.
turn off breaker in electrical panel....remove stove socket from outlet....remove rear panel from stove....undo wire connectios from broiler element....inside the oven, gently move thermostat wire out of the way....unbolt broiler plate from rear wall....remove broiler hanger and then broiler element....reverse procedure and you're all set.
Turned power off to oven. Unscrewed back plate exposing wires connected to heating element. It was difficult to unscrew the connections between them as it was hard to reach in because the oven door was in the way, but i finally succeeded. Unscrewed the bracket holding the burned out element and then attached the wires to the new element. Attached the bracket and I turned on the power. I then tested the oven and it worked.
Unplugged Stove, pulled away from wall. With smaller wrenches, took the two screw-nuts off the inside back and above that hold the broiler element in place. Since it is an older stove...took the back panel off the stove with philips screw-driver which consisted of 10 screws. Once that was removed was able to unscrew the broiler element from the two wires that provide the electricity. Used the flash light when I had to unfasten the screw-nuts inside the stove because kitchen lighting wasn't strong enough.
The customer service at PartSelect.com is wonderful. They assisted me to located a part for a 40 year old oven. Took only a few minutes to take the old one out and put the new one in. Process was pretty self explanitory.
no power going to burner when switch is on, switch bad
I followed the easy instructions and everything went well. I had the new switch installed in about 30 minutes. My wires were different colors than on the instructions but it was still easy to figure out where the wires went on the new switch. Just do not be in a hurry and make sure you measure before you break off the extension bar. My knob fit on the new switch without any of the parts that came with the switch.
First of all I did this repair because the wire to the burner shorted out. I did the wire portion first - only then did I know I needed the switch kit. (The burner was operating while my old swithch was OFF). The first (wire replacement) repair took about 10 minutes - I followed the guidance on this web-site. The second repair (The switch) took about 20 minutes. The switch ws not the same as the original. Just be careful to mark each wire as you remove them from the old switch's posts. The posts on the switch are marked and you need to place them on the like-marked corresponding posts on the new switch. All is well, my burner is operational.
Burner only worked on High and very low temperature setting.
Your "virtual repairman" was fantastic. I would have purchased the wrong part without trhe diagnostic service. It said that 53% of the time the infinite switch was the problem. In my case it was 100%. Why I put up with this problem for 6 years I will never know.
Repair job was easy but longer than the 15 minutes that it said it would take.
The replacement was straightforward, six screws. Instructions were provided with the part along with the necessary screws to fit the new element terminals. Open the breaker, verify power is off, remove the old burner. Install the new burner and mounting bracket. Restore power and test. In and out in less then thirty minutes.