The compartment behind control panel with snow

  • Customer: Victor from Houston TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 34 of 53 people found this instruction helpful
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.

Icemaker would not dispense cubes or crushed ice

  • Customer: Jeffrey from Highlands Ranch CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 25 of 28 people found this instruction helpful
Cause: Failed relays on main circuit board. Fix: Main circuit board replacement: Unplugged refrigerator. Removed 10 screws securing main circuit board metal cover (located on back of refrigerator) using a nutdriver. Disconnected 7 multi-pin electrical connectors from the circuit-board by firmly pulling each connector from the circuitboard sockets using a needlenose plyers. Depressed the small locking prong on each of the 4 plastic circuit board mounting pegs while pulling the board off the mounting pegs.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.

Ice cube production stopped; ice cube chute door is seized.

  • Customer: Bruce from Mebane NC
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 31 of 47 people found this instruction helpful
Problem: I have a black colored GE 24.9 cubic inch side-by-side refrigerator, model #GSH25KGMCBB that I purchased new in 2002. The ice cube maker stopped supplying ice cubes and the ice dispenser door stopped operating.

Repair: Unplugged refrigerator first and shut off the house water supply valve. Removed the lower rear access cover and replaced the double solenoid water valve. Icemaker and water dispenser tubing are easily removed by pushing in and holding down the white plastic collar where the tubing is inserted into each port on the valve body; no tools required to release the tubing. Hint: When reconnecting the water outlet tubing, ensure the tube diameter matches the port on the valve body. Insert each tube by hand back into the ports of the valve until they firmly seated.

Removed the control panel by inserting a small screwdriver into the three holes located on the bottom of the control panel body. Removed all of the ice dispenser door hardware and the door solenoid. The door solenoid armature was seized by corrosion. Cleaned off all of the accumulated dirt and mold with a 1:10 ratio solution of bleach and water. Replaced all of the door recess and solenoid valve fasteners with my own stainless steel #4-40 thread, 0.25" long socket head screws for longer life. The installation of the remaining hardware is the reverse of how it was removed.

The installation looks very clean now and $150 later, the ice maker still doesn't produce ice!

Root-cause analysis: I disconnected the ice cube maker water supply line from the double solenoid valve at the rear of the refrigerator and was able to blow air with my mouth straight through the outlet of the water tubing located inside of the freezer compartment; to ensure it wasn't blocked. Verified the water supply valve is not being energized! Turns out that the blinking green LED indicator on the ice cube maker is indicating more than the troubleshooting guide does about that because the white colored insulated conductor in the electrical harness for the ice cube maker is not energizing the solenoid on the water supply valve!

Conclusion: the ice cube maker assembly is next on the list of replacement parts!!

Water is not coming from front door dispenser, but ice maker works well

  • Customer: BABU from GRAND PRAIRIE TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
  • 25 of 29 people found this instruction helpful
On one severe winter cold night my fridge dispenser door stopped water supply, but ice maker was working. First I disconnected power supply to the fridge then turned off main water supply from the wall to fridge and with wrench set disconnected water supply pipe from wall to fridge while disconnecting the pipe make sure to collect the water from the both end pipes. Then removed the cardboard from the back side of the fridge. I disconnected the blue element (dispenser water) the red element (ice maker). [DOUBLE OUTLET WATER VALVE]. If you would try to pull the pipes white (dispenser water) and black (ice maker) you woudn't succeed because once the the white and black pipes are insereted into the water valve those pipes are clamped tightly in the valve. So I cut off those pipes and removed the old water valve, then I conncected the new water valve first conncected those white and blue elements and inserted the white and black pipes pushed in closed with round plactic caps comes with new one.I reconncected the main water supply pipes from wall to the frige and turned on the water supply from wall and plugged the power supply. First surpisingly I doubted it will work, actullay the water dispnser did'nt work immediately I have to wait 2 to 3 hours of time, in the mean time I checked the pipe connections from the bottom of the front left side door ( if you open the two doors bottom you can see the plastic cover it can be removed by pulling towards and pushing in you can close it back into normal position) which water supply pipe comes through the bottom of the door to water dispenser. I disconnected the connector and pusheed the dispensor several times to flushout any leaky water or air then I reconnected the pipes to the connector. I pushed the dispenser with a cup to dispenser, it started working as it is normally. While I was working my 7 years old son helped me as he always eager to learn and explore things.

Received the Temp Sensor but no documentation how to replace it

  • Customer: Stephen from Sebring FL
  • Difficulty: Very Difficult
  • Time to Complete: More than 2 hours
  • Tools Required:
  • 27 of 35 people found this instruction helpful
I still have not be able to replace the sensor as I've been unable to locate any info, or figure out where it is located. The water valve was easy to replace and took less than a half hour

After looking further into your website I found all the info, diagrams and instructions to replace the Temp Sensor, which was not too involved, thank you. Now to wait and see if this was the cause and my Refrigerator is up and running again

Quit making ice.

  • Customer: Joe from Brentwood TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 25 of 31 people found this instruction helpful
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.

Pieces broke off Auger and Cover cracked.

  • Customer: Larry from Georgetown TX
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers
  • 29 of 43 people found this instruction helpful
Remove and empty ice maker from freezer . Remove two screws from bottom to remove the front panel (cover bucket). Remove one screw which holds the deflector on top of the bucket.(tray which holds the ice curbs). Remove one screw that holds the clip that holds the wire actuator rod.

To remove the the ice crusher/dispenser mechanism from the bucket I used two table knives Spread one side of the bucket with one knofe and pry up with the other to get the retainer wedge free from the bucket side. Repeat on the other side. Once the retainer wedges are free the ice crusher/dispenser with the auger attached can be lifted free from the bucket.

With a spanner wrench remove the nylon nut from the shaft. NOTE: THIS IS A LEFT HAND NUT. Note the orientation and relationship of the crusher blades. They must be replaced properly for the system to crush ice and dispense cubes correctly. Remove blades and spacers from Auger.

Reassemble in reverse order. Be sure to get the actuator rod in place in the cam for the dispensor cover before sliding the crusher/dispenser mechanism totally in place. If not in the cam correctly the crusher/dispenser may have to be removed again.

Although a little difficult the first time the project is easily done by an adventourous handy person.

Water dispensor would not shut off

  • Customer: John from Mason OH
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
  • 29 of 43 people found this instruction helpful
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.

The difficult part was accessing the area to get to the micro switch.

The trim had to be removed, then the cover.

Then one unplugs the board and removed the face plate which also contains the micro switch.

Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.

Then reverse the removal procedure.

Then on to the double outlet replacement.

Suggest watching the installation video for the replacement although it was really a straight forward repair.

Two things to remember.

1. Unplug the fridge

2. Shut off the water to the dispenser

Overall it was not bad at all.

This was my first attempt at refrigerator repair and it went well.

Good luck on yours.


This seems to be a design problem because I have to replace this part about every other year since we bought it. I tried to talk to GE but all they want to do is send a service man out to replace the part for about 100.00, But I do it for around 15.00. I just think they should find out why the rubbe

  • Customer: Jeff from Columbia City IN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 25 of 33 people found this instruction helpful
The repair is easy, just pop the grill off around the ice and water door, then there are 4 screwws to take out so the touch pad can be moved out of the way to unsnap the old door assm. and snap in the new one and wait about a year and a hald to order another one!!!!!

water running slow

  • Customer: David from Tacoma WA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 24 of 31 people found this instruction helpful
unscrewed old filter by hand, installed new filter.

ice maker leaked water slowly and froze the cubes together

  • Customer: Steven from Cave Creek AZ
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 27 of 41 people found this instruction helpful
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.

water and ice maker stopped working

  • Customer: Robert from Sandston VA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 21 of 23 people found this instruction helpful
Removed the cover on the bottom of the rear of the fridge and the top left of the fridge where the tubbes exit.. Then just simply disconnect the tube coming from the fridge and the supply line. Next go inside the fridge, remove the cover of the filter mount, and remove the 2 screws securing the filter mount in place. Now pull the tubes through the opening and reinstall in reverse order.

water & Ice disspenser quite working

  • Customer: Michael from Otsego MN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 22 of 27 people found this instruction helpful
first replace the solenoid behind the front display. than replace the mother board on the back side of the fridge due to a relay being burned out on it.

GE Wanted $300 + to come out and do the repair.

With partsselect and a little time I cut that cost in half.

Thank you,


freezer cold / fridge warm

  • Customer: Mark from Mancos CO
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 22 of 28 people found this instruction helpful
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go

ice despenser door would stick open and frost up to the point of of ice not coming out

  • Customer: joe from raleigh NC
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 25 of 37 people found this instruction helpful
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel