Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
I removed all contents from the lower shelf. I, then removed both of the pull out drawers. Secondly, I removed the lower glass shelf and the glass support tray. At this point all four plastic shelf supports were accessible. I removed the inner screw from all four supports and replaced with four new shelf supports. Then reassembled in reverse order. Very easy to do!
The repair goes much easier if the door is removed. The door is bulky and that's the difficult part. Once its on the table, unscrew to get old one off, put new one in place and re screw. (there are many screws) Then bulky door needs to be placed back onto the refrigerator. Again difficult positioning, weight, bulky. The door comes off and goes on very easily (2 mins to get off, 10 to put back on). Just 3 lower screws. This job could have taken less than an hour if I had started with a removed door.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
Broken left side slide rail for the meat/cheese bin
Removing the broken rail was very difficult. There is a small notch that actually holds it in place. To remove the old rail, there was a hole in the metal bracket next to where the notch was. You had to apply pressure through the hole to the rail to slightly bend it to get it to release the notch to slide the old rail out. After the old rail was removed, the new rail with rack wheel installed, slid in and snapped into place very easily.
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
The first order of business was to find a supplier for the gasket and to make sure that the right one was ordered. This was done with out a hitch @ Part Select and at a cost less than the retail stores. The right Gasket was ordered thru Parts Select
Only difficulty was to start the install of the replacment . Need to start at the hinged corner of the door Top & Bottom for a good fit and less hassel.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
freezer was leeking in the fridge and floor.Freezer drain was cracked
First I removed the screw that held the housing in place. I then pulled the housing out about 3 inches and disconnected the wires.Put old housing next to new one and started stripping old housing and building new one.Reconnected the wires and screwed in place 15 min max
Ice buildup on the bottom of the freezer, water dripping into the refrigerator
After unplugging the refrigerator, I used a hairdryer to melt the ice sufficiently to be able to remove the freezer rear panel with a nutdriver. I also removed the ice-maker for easier access to the components behind the panel, using a nutdriver. Once the panel was removed I melted more ice at the bottom of the evaporator housing. After partially melting the ice in the drain tube, I poured hot water down the drain tube until it cleared, signaled by the sound of the water dripping into the drain pan. I next removed the clip-on Bimetal thermostat from the copper line going into the evaporator and snipped the two wires to remove it. I installed the replacement thermostat with crimp-style connectors and pull-tested them. I also replaced the timer board that is located below the freezer, below the top shelf, using a nutdriver. I replaced the circuit board as a precaution that the thermostat may not have caused the problem. I didn't change the heater inside the freezer as it checked out to have the same resistance as a new one. I tested the removed thermostat using a glass of ice water but it remained in the open condition, using an ohmmeter. (I later checked that thermostat after the freezer was running and it did close, and returned it to the open position by heating it under the hot water faucet. I suspect that it didn't work properly, or the timer control board was faulty). After re-installing the back panel and ice-maker and plugging the refrigerator into the power receptacle, it worked very well, and has done so since the repair.
It was easy breezy!! I felt like an empowered woman that I did it myself. I simply removed the old shelf supports with a screwdrive and inserted a screw thru the new supports and screwed them in.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid