just quit working
Bought a new
capacitor.
Parts Used:
Run Capacitor
  • Denise from Lowell, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not freeze
unplugged, removed old parts, replaced with new
Parts Used:
Run Capacitor Compressor Start Relay
  • John from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit working
Followed the steps in the video on your site, really easy to do.
Parts Used:
Refrigerator Ice Maker Assembly
  • Steve from ORANGE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
16 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker would not make ice
un plug fridge. removed ice maker from fridge. loosen 2 mounting screws. lift unit in slots to get over heads of screws. unplug wire harness. remove cover. remove 3 screws from control housing. remove 2 motor mounting screws. unplug motor wires from switches w/needle nose. installation is the reverse. plug in fridge turn on icemaker. takes 10 to 15 min to start to cycle.
easy and cheaper than new fridge or ice maker
Parts Used:
Replacement Ice Maker
  • paul from traer, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stoped working and the water dispenser also stopped working at different times.
Pulled unit away from the wall. Removed backing from lower controls and compressor. Unhooked water lines and wires to solonoids and removed malfunctioning valve. Hooked new valve to the the plastic water lines, connected wires and mounted new valve to the back support plate.
Parts Used:
Dual Outlet Water Valve
  • Roger from Rochester Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped working, cooling.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Parts Used:
Compressor Start Relay
  • Jennifer from Jonestown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Parts Used:
Run Capacitor
  • Vicki from Johnson City, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Parts Used:
Run Capacitor
  • Frederic from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
Parts Used:
Defrost Timer - 60Hz 120V
  • Doug from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer coil was frosting up blocking airflow to refrigerator side
I first unplugged the refirgerator. Note the time because the refrigerator should be unplugged at least 30 minutes before plugging back in (see end for why). A trouble light is necessary to see adequately. I removed the shelves and draws and put food in a picnic cooler. I took off the lower panel in the back of the freezer, and defrosted the coils with a hair dryer. I unplugged the wires to the defroster, and then the screw holding the coil to the back of the freezer side. I lifted up on the coil unit to clear the blade that inserts into the drain. I removed the bands on the top of the coil that hold the heating unit in place. I tilted the bottom out when there was clearance, and pulled the defrosting unit down and out. I replaced the new one, and reversed the procedure, and then plugged the wires back into the new defroster unit. The bands on the top should be secured before putting the coil back in place, as well as the foam spacers on top of coil, put the two wires back in the plastic clip that keeps them away from the fan and pipes. Replace lower freezer cover panel and screws. Put shelves and food back in. If at least 30 minutes have passed, plug the refrigerator back in. If you don't wait that long, their will still be pressure in the compressor and it will not start to cool properly right away. It works perfectly now. TIP: check the end of the drain hose periodically by taking off the lower back cover and pull th hose out - not hard to do. Mine plugged from dust and lint build up backing up into the end of the hose so water didn't drain out, and ice built up causing the defroster coil to burn out. I cut a little off the hose so the water level would not rise up into the hose, but the hose would still stay in place in the plastic holder.
Parts Used:
Defrost Heater
  • David from Chetek, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
wonnt defrost
removed back cover from freezer to replace defrost stat. removed cover from refrigerator to replace defrost timer
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • bruce from grand haven, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The plastic that held the drawer in place broke
I called Part Select and ordered a new drawer. They got the item to me within 3 days! I would definitely recommend them to a friend.
Parts Used:
Lower Crisper Drawer Lower Storage Drawer Front
  • Ann from Marriottsville, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the LH guide rail on the drawer broke off
I slid upward and disengaged the front cover off the old drawer. Slid down the same front cover on the new one, slid the drawer in and it was like new again.

Initially i though this whole thing would take weeks, The website provided detailed exploded views, I ordered the part and it arrived in 2 days. It was too easy.
Parts Used:
Deli Drawer
  • Andrew from Jackson, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer kept icing over, refrigerator too hot
First, I unplugged the appliance. Safety, first.
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Parts Used:
Defrost Thermostat
  • debra from new washington, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Won't Auto Defrost
Make sure unplugged the frig before doing any repair. Just like other DIYers. opened up the evaporator located inside the freezer. Replaced the defrost thermostat, there's only 2 wires, so just make sure which is positive, which is negative. Replaced the defrost timer located on the bottom front of the frig. There's on 2 screws to unscrew. All those work took me less than half hour. Turn on the frig., now it works like a champ again. Hope it will last another 10 years.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Ricky from San Francisco, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!