routine maintenance
slide old filter out and insert new one
Parts Used:
Air Filter
  • fred from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge leaked water all over my kitchen
I watched the video and followed every step as outlined. It worked perfect, until I reconnected the supply line to my triple water valve. I used the old compression fitting and the compression nut. I should have cut the line and installed a new fitting and nut. The water on the floor the next morning reminded me of that. So back out I went and replaced the compression fitting and it has been as good as new. The ice maker took a few cycles to work again, I think it needed to fill the line with water first. But I have a huge sense of pride every time I hear water dispenced or ice dump in the freezer. Thanks for the help and encouragement!
Parts Used:
Refrigerator Water Inlet Valve
  • Craig from Eastlake, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
LEAKED WATER AFTER USING WATER DISPENSER
DID IT JUST LIKE THE VIDEO SHOWED. UNHOOKED ELECTRICS, CUT TUBING, HOOKED UP ELECTRICS THEN TUBES TO NEW PART. PIECE OF CAKE.
Parts Used:
Refrigerator Water Inlet Valve
  • Mark from LANCASTER, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Switch too loose so no longer triggered by the door.
Googled it on Youtube - unplugged the fridge, used a paint scraper to loosen the old light switch, unplugged it from the electrical source, connected the new switch, replaced the whole unit into the proper location and pushed it firmly into place.
Parts Used:
Light Switch
  • Linda from BOZEMAN, MT
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Switch not working properly
After unplugging the fridge, I took a small flat headed screwdriver and carefully pried off the light switch from the inside, right side of the refrigerator. I disconnected the 2 wires from the switch and replaced it with the new switch and pushed it back into the frame of the fridge. Done !! Very very easy !! Thank you
Parts Used:
Light Switch
  • William from ORMOND BEACH, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filter was dirty
Just push the button on the top right hand and pull the filter out; then proceed to instal the new one pushing it in place. It's really an easy operation!!
Parts Used:
Water Filter Base
  • Angel from Tampa, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wasn't "winterized" ..This is a summer home, the cold winter cracked the water valve
I put the new unit up to the old one to see exactly how it goes, took the 2 screws holding the unt off...Took the 3 water lines off with adjustable wrench, put back exactly the same way and it worked with no leaks
Parts Used:
Refrigerator Water Inlet Valve
  • Jimmy from west sayville, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
The part was easy to install and solved the problem! We had ice within hours. Thanks PartSelect!
Parts Used:
Refrigerator Water Inlet Valve
  • ruth from vancouver, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker failure, broken auger housing
Remove ice maker, completely disassemble, being careful with the styrofoam around housing. This is a very weak part and takes much load from auger. Use a white, high strength tape to bind around the housing with, (very important) or you'll be doing this again as it is a failure point.
Parts Used:
HOUSING-CRUSHER
  • Don from NEW BERN, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I let value was leaking its self
Undo a few bolts unplug power and unhook water lines then recut all lines and push in to new value
Parts Used:
Refrigerator Water Inlet Valve
  • Mitchell from FOXWORTH, MS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filter would not seat without releasing itself.
Following previous installation instructions was very useful. Would add that the nut driver needs to be 1/4 in and to release the water lines from the valve body, simply squeeze the blue ring toward the valve and pull on the water lines at the same time. Simple fix!
Parts Used:
Water Filter Base
  • Lawrence from HUNTINGTON, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Valve body separated : major leak.
Write down where tubing goes, wiring is color coded.
Parts Used:
Refrigerator Water Inlet Valve
  • Robert from NASHVILLE, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water line retainer missing in one port of new valve
carefully removed retainer from old valve
Parts Used:
Refrigerator Water Inlet Valve
  • William from DUCK RIVER, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve was leaking
The u tube instructions were exactly what is needed. I had to cut off the old plastic pipes. My pipe had threaded connectors. Pex push on connection is super easy. You don't really need a block of wood to cut it if you have a sharp utility blade. If if you are sure this is the problem this is a really easy fix. Steps 1 turn off water at wall unplug electric also 2. Disc line at valve on refrigerator 3. Remove 2 screws holding valve 4. Pull valve out and remove plastic hoses and electric connections pay attention to color of pipe and electric connection. Mine were color coded. Had to cut off thread connectors. Reattach in reverse order or do one at a time. Check for leaks.
Parts Used:
Refrigerator Water Inlet Valve
  • Randy from GUYMON, OK
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the EI28BS56IW1