old unit was worn out from over use
simply push new ice bucket into position and your done. works better than new! saved 200.00 from calling in a tech for the repair. the part sent is a original GE part not an aftermarket part.
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom. The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.
When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.
Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.
Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.
Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Helix plate keyed hole was stripped keeping the helix from rotating with the auger. I bought an auger too, but didn't need it as the auger is a harder material than the helix plate and was not worn where the plate contacts it. TAKE PICTURES of the dispenser blades area before taking them off the auger shaft.
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.