Models > CSX25GRBCWW > Instructions

CSX25GRBCWW Hotpoint Refrigerator - Instructions

All Instructions for the CSX25GRBCWW
91 - 105 of 938
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
leaking water / icemaker valve
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.
Parts Used:
Dual Inlet Water Valve
  • Lorry from Bentonville, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking all over freezer compartment
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.
Parts Used:
Dual Inlet Water Valve
  • Mary from Langhorne, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Will not make ice
Bing , Bang, Boom.
Parts Used:
Ice Maker
  • GEORGE from ELIOT, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burnt out heater defront unit
1. Turned unit off and removed freezer shelving
2. Removed 5 screws on back pannel to expose heaters
3. Deforsted coils with a hair dryer and removed ice cubes
4. Compaired new defrost harness to the existing
5. Removed 4 screws holding the defective harness
6. Installed new heater harness with 4 screws and elec. plug
7. Reinstalled back pannel and shelving
8. Turned unit back on
Parts Used:
Defrost Heater with Thermostat
  • Fred from Martinez, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
Parts Used:
Condenser Fan Motor - 115V
  • John from Divide, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Parts Used:
Dual Inlet Water Valve
  • Drew from Spring Lake, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Parts Used:
Dispenser Door Assembly or Flapper
  • Tim from The Woodlands, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Top of refrigerator and freezer are warmer than bottom. Also, a large amoutnt of ice build up in the back of the freezer.
**Before you order a new part make sure you get the FULL model number off of the back of the refrigerator**
To even get to the back panel I had to melt the ice in the back of the freezer with a hair dryer. Once the ice was gone I removed 5 screws that held the panel that covers the coils. I melted more ice from the coils. I disconnected the connector for the old heater wiring harness and pooped the thermosat off. Then, removed the screws that held the heaters (2 per heater). Installed new heaters and connected wiring harness. Snapped new thermosat on. Replaced coil cover and plugged it back in.
Parts Used:
Defrost Heater with Thermostat
  • Andrew from Decatur, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Parts Used:
Dual Inlet Water Valve
  • Eric from Rose Hill, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Parts Used:
Defrost Timer
  • Bill from Columbiana, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not defrost
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
Parts Used:
Defrost Heater with Thermostat
  • Richard from Quakertown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit dispensing and crushing ice.
Ordered new auger and ice bucket assembly. Removed old door and with four screws I attached it to the new unit. Works very well!
Parts Used:
Auger and Ice Bucket Assembly
  • Charles from Odessa, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer coil iceing up
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
Parts Used:
Defrost Heater with Thermostat
  • Paul from Palmdale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Gasket had split and causing excess sweating inside of refrigerator whick was cauing water to drain out the front door damaging the floor.
Very simple fix. I loosened all screws with a nutdriver, removed old seal by pulling it out from under the retaining plate. replaced new seal and tightened screws.

Great fit!
Parts Used:
Fresh Food Door Gasket
  • Todd from Bainbridge, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Parts Used:
Defrost Timer
  • Hop from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSX25GRBCWW
91 - 105 of 938