Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Lower door hinge cam worn out/door dropped, not sealing
Removed door contents to lower weight (good time to clean/disinfect door compartments), blocked and shimmed door up to correct fininished height. Removed lower hinge components (make sure shims positions are noted). Replaced w/new components and removed blocking. Easy job, should have done sooner.
My wife called me at work and said the refrigerator was "peeing" on the floor.
When I got home I pulled the refrigerator away from the floor, checked all the water lines for leak evidence, and then took the back panel off to check everything behind. The water valve was leaking at the hose insert locations. I turned off the water, spent less than 5 minutes disassembling the valve from the rerfrigerator, and got online to buy another one. The part arrived several days before expected, and it took me less time to install the new part than it did to take the old one out. Now all I have to do is repair the floor damage I caused when pulling out the refirgerator!
The biggest problem was that the part was NOT available from GE. Part Select had the part, it was easily identified on their website and it couldn't have been easier to order it.
The repair from GE would have cost me hundreds of dollars. Thanks Parts Select.
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door. Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block. I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Removed goods in fridge, removed shelf, unscrewed 2 screws, installed new drawer slide with 2 screws, replaced shelf, inserted drawer. Most of the time was moving the stuff in the refregerator. If the fridge was empty it would have taken me 2 minutes.
UNPLUGGED REFRIGERATOR.. removed top shelf in refrigerator..removed back plate covering controls..removed two screws holding control housing..removed two screws holding defrost timer..unplugged defrost timer and plugged new timer in..put all parts back in place with procedure reversed..
Turned the power of to the fridge took the food out of the freezer put in the fridge took out all the shelves and took off the panel to get to the coils. I used a hair dryer and a shop vac to defrost the coils used the shop vac to suck up the water as the ice melted also put some paper towel in the drip tube so the water would not go to the drip pan. Took off old defrost heater which was a single heater the new on was a double heater fished out the blue wire from the left side of compartment and ran it down the right side plugged both wires into the heater mounted it into place and put everything back. Turned on fridge and it has been working fine ever since. Thanks for the last person that did this I read his review and it really was that easy Thanks Jerry
removed 2 - 1/4" screws and 2 phillip screws to take off the evap cover, then 2 phillip srews to take out the defrost heater assembly, replaced and put everything back together. no problem. I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
Freezer was not freezing foods completely or making ice properly. It was running almost 24/7. It was not defrosting and ice was building up on the back wall. The refrigerator food drawers were freezing fruits and vegtables.
Great Service! Received the part the NEXT DAY!
We originally called a service technician. He came the next day and said the mother board was no good. He order a new one and replaced it a week later. Total part & labor cost: $185.00 (Remember we're without a working refrigerator the whole time the part is on order) Two days later the freezer is doing the same thing. We call the tech again and he seems confused and says it could be the heating element, he'll order one at no charge and replace it for us free. He never comes back with the part and does not answer our 2 dozen phone calls. I checked the element myself and saw that the tube had been scorched, like a burnt out light bulb. Searched for parts on internet and found this great site. "Partselect.com" REPAIR: Refrigerator had been unplugged for a few days to defrost ice build up in freezer. First, I removed the shelves from freezer compartment, removed the back panel and removed screws holding heater element in place, I unplugged the two electrical leads and plugged in new part. AS EASY AS THAT !!!!! I reinstalled the screws to hold the element, installed the back panel and replaced the freezer shelves. I plugged the refrigerator back in and within hours the freezer started making ice again. It's been about 3 weeks and we have not had a problem since. Fantastic Service and instructions and Inexpensive !!!! I will use this site again, if needed, and will recommemd to anyone who needs parts.
Cold water dispencing was becoming slower and volume of ice was becoming less.
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinstalled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.