Rust on parts

  • Customer: Sally from Allen TX
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 10 of 11 people found this instruction helpful
I recommend taking a picture of any part before it is removed. Remove all screws. Use the diagram provided by this site for the dismantle of the ice bucket parts. I replaced the plate and ice auger. I found that my rusted screws for the plate would not fit the new plate, so I bought replacement screws at Home Depot. After I got all the blades off, I realized that I should have probably replaced a couple of them as well. Next time I decide to repair an item, I will totally inspect all parts before ordering. Order was shipped immediately. Postal Carrier showed me why he dropped off at another location which caused a delay of a couple of days. Not the senders problem. I had a hard time remembering just how the rod on the side was suppose to fit. I should have taken a picture. (laughing) I finally figured it out. My ice maker is as good as new. So happy I did this. My husband always says: " Just get a new refrigerator." I was raised to fix things until they just die. He was so impressed that I was able to follow the diagram and re-install the ice bucket. All is great. I will use this site again. They are a great company. I am sure I saved hundreds of dollars for a repairman who would have replaced the whole unit and not taken the time for the repair and replacement of parts. This was just "as easy as pie".

water line leaking behind refigerator

  • Customer: Michael from Merrimac MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers
  • 10 of 11 people found this instruction helpful
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks

Replace Dual Inlet Water Valve

  • Customer: Timothy from West Windsor NJ
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 15 of 26 people found this instruction helpful
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.

New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.

The refrigerator section of my side by side was not getting as cold as it should have been.

  • Customer: Wayne from Magnolia TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 9 of 9 people found this instruction helpful
It was easy after finding PartSelect online. It wasn't obvious at first that my evaporator core(in back of freezer side) was frosting over, (since I have a flat white panel that is about 8 x 30 inches covering it), until I reached inside and ran my fingers over the cover and noticed a thin layer of frost on it. At this point I told my buddies to go get ice for our beer cuz I was fixin to do a lock out/tag out on the Fridge. Seriously, Do disconnect the electrical power before taking it apart. After taking the 9 screws (6-1/4" hex heads & 3-#2 phillips)out and removing the panel, I saw that the evaporator core was completely frosted over. I then put a large towel in the bottom and let it thaw for a day. Next day after getting the old Defrost Heater Kit with Thermostat out (4-#2 phillips, plug-in electrical connection, thermostat snap on clip) , I noticed it was burnt inside the filaments and did not pass the continuity test. I then ordered my part from PartSelect and took the oppurtunity to clean my fridge spotless. 3 business days later, I received my part, installed it, and now have a "like new" refrigertor. Actual repair time - 30 minutes, Overall down time - 4 days, Saving the cost of a new Fridge - a heck of lot more beer!

Light switch inside refrigerator wasn't working

  • Customer: Erick from Elmhurst NY
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 9 of 9 people found this instruction helpful
First turned off power and removed top shelf.
Then I used a flathead to slowly pry the switch out by the two sides. You just anlge ita bit and it slideds out easily. Then I disconnected the wires from the old switch, connected the new one and installed the new switch by snapping it back into the cutout.

CAMS ON FREEZER DOOR BROKE

  • Customer: WALTER from FROSTBURG MD
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set, Wrench(Adjustable)
  • 9 of 10 people found this instruction helpful
REMOVED TOP HINGE AND ELECTRICAL CONNECTOR (FREEZER DOOR HAS ICE AND WATER DISPENSERS) THEN HAD TO TURN OFF WATER SUPPLY TO UNIT AND DISCONNECT THE HOSE TO THE DOOR AND REMOVE THE SPRING PROTECTOR FROM THE HOSE -- THIS REQUIRED REMOVAL OF THE COMPRESSION FITTINGS IN THE WATER LINE SO SPRING WOULD COME OFF OF THE TUBE.
THEN REMOVED BOTTOM HINGE FROM THE DOOR AND USED SAW TO REMOVE THE RIVET THAT HAD HELD THE CAM TO THE HINGE, USED A NUT AND BOLT TO ATTACH NEW CAM. PUT OTHER CAM (USED TWO) IN THE HINGE AND REPLACED LOWER HINGE UNIT ON THE DOOR. THEN REATTACHED BOTH HINGES TO THE REFRIGERATOR AND LINED UP THE DOOR PUT THE SPRING PROTECTOR AND COMPRESSION FITTINGS BACK ON PLASTIC TUBING AND RECONNECTED THE WATER SUPPLY AND ELECTRIC FITTING, TURNED ON WATER TO UNIT AND PRAYED THERE WERE NO LEAKS. PRAYER WAS ANSWERED, THE WATER DISPENSER WORKED PROPERLY AND THE ICE MAKER FILLED WITH WATER SO I THEN REPLACED THE HINGE COVER ON TOP OF THE UNIT AND THE GRILL AT THE BOTTOM AND HAD A PEPSI. A FEW YEARS AGO I HAD REPLACED THE CAMS ON THE OTHER DOOR WHICH HAD NO WATER/ELECTIC CONNECTIONS AND WAS A MUCH SIMPLER JOB.

Compressor overheating - Fridge not Cooling

  • Customer: CHRIS from LAGUNA NIGUEL CA
  • Difficulty: Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 10 of 13 people found this instruction helpful
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.

Ref/frig not cooling

  • Customer: Greg from Vicksburg MS
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 9 of 10 people found this instruction helpful
Removed the 4 screws holding the back panel in freezer compartment and then removed panel. Removed the 4 screws holding defrost heater and removed it. The replacement parts fit perfect , plug the new part in and bingo my frig is operating like a new one. Took about 15 minutes to make the repair. Took longer to defrost the ice buildup on the coils ( 1hr ) than to do the repair (15 min). I can't believe i would have been paying an appliance repairman to hold a hair dryer for an hour. Your diagrams showing where the various parts are located on the appliance are invaluable. Would recommend PartsSelect to anyone and I am sure that I will be ordering parts for my other appliances as needed. Thanks

Flapper was stuck open. Old and warped.

  • Customer: James from Virginia Beach VA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 11 of 16 people found this instruction helpful
Replaced flapper

Refrigerator door wouldn't close right

  • Customer: Anthony from Highland Lakes NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 10 of 14 people found this instruction helpful
GET 2 "door closing cams"
Yep. same as some others here. found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. very easy. bottom bracket has the broken cam riveted to it. need hacksaw to get this off then punch it through with hammer and a screwdriver. this is the only part that took a little while. replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half.
Replace the closing cam that is on the bottom the the door as well. even if yours isn't broken. replace it anyway. put door back on and done. not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. good luck

water valve leak

  • Customer: Scott from Columbus IN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 8 of 8 people found this instruction helpful
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.

ice maker not making ice

  • Customer: Cristina from Los Angeles CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours

Ice Maker was leaking all over freezer compartment

  • Customer: Mary from Langhorne PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 9 of 11 people found this instruction helpful
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.

Replace ice maker

  • Customer: Gary from Glendale AZ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.

ice would not dispense

  • Customer: john from montgomery TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 10 of 14 people found this instruction helpful
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.
All Instructions for the CSC22GRSAAD