The regrigerator would not defrost properly. After doing some online research, I determined that the Defrost Heater was no longer working.

  • Customer: David from Lakeland FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
First, I had to remove the back panel in the freezer. This exposes the cooling coils and the Defrost Heater which is located toward the bottom underneath the cooling coils. There are four screws that have to be removed before the old Defrost Heater can be taken out. There are two wires that go from the Defrost Heater to the power connection. These wires are blue and pink. I had to remove some pieces in the back at the top of the freezer to expose the power connection for the Defrost Heater. These pieces were held in place with phillips screws, so they easily came out to reveal the power connection. The power connection is a simple plug-in type. The Defrost Thermostat is also included with the new Defrost Heater. This is a round piece which is clamped onto the Cooling Coils. I removed the old Defrost Thermostat. It is connected to the same power connection with the Defrost Heater. After I mounted the new Defrost Heater and Defrost Thermostat and connected the power, the refrigerator has worked perfectly.

Failed Icemaker

  • Customer: GARY from PARRISH FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 14 of 28 people found this instruction helpful
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.

Flapper not sealing. Frost buildup on inside of freezer door

  • Customer: D from ZELLWOOD FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved

Defrost Thermostat quit working

  • Customer: Jimmy from Palmer TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.

Refrigerator door wouldn't close right

  • Customer: Anthony from Highland Lakes NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 9 of 13 people found this instruction helpful
GET 2 "door closing cams"
Yep. same as some others here. found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. very easy. bottom bracket has the broken cam riveted to it. need hacksaw to get this off then punch it through with hammer and a screwdriver. this is the only part that took a little while. replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half.
Replace the closing cam that is on the bottom the the door as well. even if yours isn't broken. replace it anyway. put door back on and done. not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. good luck

replace icemaker

  • Customer: Conrad from Oglesby IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
I slid the old ice maker (which was rusty) out of the freezer. I emptied the ice cubes. I unscrewed the 3 screws holding the plate to the old ice maker. I attached the original plate to the new ice maker/ auger unit with 2 screws. The new icemaker assembly did not match up with a 3rd screw hole. The 2 screws seem to be holding securely.
I reinserted the new assembly. Shorly after this nice clean ice cubes began to form. Works very well!

leaking water / icemaker valve

  • Customer: Lorry from Bentonville AR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 8 of 11 people found this instruction helpful
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.

Refrigerator & freezer became warm.

  • Customer: James from Garland TX
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers, Socket set
  • 8 of 11 people found this instruction helpful
Unplugged the refrigerator. I took all the food items out of the freezer, took out the ice bin and shelves. Then I unscrewed the back panel and removed it. The freezer coils were frozen over with ice. Then I used a large fan to thaw the ice and cleaned up the water with towels.
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!

NOISEY MOTOR, BEARINGS OUT, DYING

  • Customer: PERRY from VANDERBILT MI
  • Difficulty: Easy
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Wrench set
  • 7 of 8 people found this instruction helpful
REMOVE BACK COVER, EXPOSING FAN MOTOR. TURN OFF POWER, REMOVE NUT ON FAN BLADES. REMOVE FAN CAREFULLY, DO NOT BEND. UNHOOK WIRING HARNESS. REMOVE THREE SCREWS THAT HOLD THE MOTOR ON THE BACK FRAME. REMOVE OLD MOTOR, INSTALL NEW. CAREFULLY, REINSTALL FAN BLADES, HOOK UP WIRING, AND YOUR READY FOR TRYOUT. ALSO DO SOME CLEANING WHILE YOUR THERE. CLEAN OLD FAN BLADES WITH HOT SOAPY WATER OR CONTACT CLEANER. EVERYTHING RUNS BETTER CLEAN!

Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix

  • Customer: Osvaldo from Miami FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench(Adjustable)
  • 8 of 11 people found this instruction helpful
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.

Door hinge cam crumbled

  • Customer: Ralph from Portland OR
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 7 of 8 people found this instruction helpful
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.

ICE MAKER CAP BROKE

  • Customer: TIM from GRETNA LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 11 people found this instruction helpful
IT TOOK ME ABOUT 15 MINUTES TO COMPLETE THE REPAIR, 1ST I EMPTIED THE ICE MAKER, THEN I REMOVED 4 SCREWS FROM THE REAR OF THE ICE MAKER TRAY AND TOOK THE PLASTIC PIECE OFF OF THE AUGER. I REVERSED THE STEPS AND PUT IT BACK TOGETHER.

broken ice maker

  • Customer: robert from bensalem PA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 8 people found this instruction helpful
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.

bucket drive shaft disengaged from motor drive

  • Customer: Paul from Ashton MD
  • Difficulty: Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Pliers, Screw drivers
  • 8 of 12 people found this instruction helpful
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.

Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.

  • Customer: Tim from The Woodlands TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 9 people found this instruction helpful
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.