Frig not cold at all,Freezer was all defrosted
Well the frist thing I did was get out the all the paper work and look under trouble shooting.This frig has a list of codes to try to help narrow down what parts might be bad.Well at frist it seemed it was a Defrost Thermastat?Well thanks to PartSelect it showed me right where it was and step by step how to remove and replace it.It took me over 2Hr's,after that I let the frig run all night and the next morning(yep warm frig)not the part I needed,well now Im mad,the local part store said you need a 3in1 jump starter easy to in stall at $50.Can'nt bring parts back no way weather thier opened or not.So get home and can'nt see how this jumper is going to wire up to my compresser?So on to the Web site to get some info,find out that this part gets a thumb's down,it puts out more volt's then needed and kills your compresser the reviews where very help full.So back to PartSelect to see more info,then I spoted the Overload/Relay and went to the back of my Frig and this part just plugs right into the compresser,I pulled it of with pliers and Bingo a burn spot melted right through the Overload/Relay.Ordered the right part the same as the old one.Put the part in and Bam,compresser fired right up.If I only did alittle more home work I could off saved alot of head ach and money.Thanks PartSelect I'll alway's click on to your web site for future parts and advise.
Parts Used:
Compressor Start Device and Capacitor
  • Denise from SOUTHINGTON, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
64 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Build-up in freezer
We have a bottom freezer refridgerator that kept having ice build-up in the freezer. We thought it was being caused by people (kids) not fully closing the freezer door. The ice build-up was really thick especially behind the rear cover. i defrosted the freezer about 3 times and it kept happening. We replace the timer (PS2065577) and have not had a problem since. The timer is actually in the refridgerator compartment , but controls the defrost cycle in the freezer.
Parts Used:
Defrost Timer - 120V 60Hz
  • Dave from San Diego, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
67 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cold but freezer was cold
removed ice maker and wire shelf. removed back panel screws and tilted forward. removed 2 screws holding motor bracket. swapped fan blade and reassembled
Parts Used:
Freezer Evaporator Fan Motor - 115V 60Hz
  • jarrett from PALM DESERT, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
65 of 79 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold, refrigerator warm
For the timer, I removed the upper light panel in the refrigerator with a screwdriver and the defrost timer is just plugged in. Easy fix, however most websites were saying it was located down by the kickplate. The thermostat was I think was te real culprit of my problem. I removed the back plate of the freezer after removing the pullout drawers. It just took four screws. The vent/grill just pops out if squeeze it to one side and slide out the other. Then swivel out door. Note that I do not have the ice maker installed in mine so yours may have a another step. I unplugged the refrigerator at this point and grabbed my blow dryer. I melted all the ice that had formed on condenser. The thermostat is located to the right of the fan. Unclip old thermostat and snip wires with enough slack to attach new one. Attach with wire nuts, reclip and start moving in reverse back to the beginning. 7days and no problems!
Parts Used:
Defrost Timer - 120V 60Hz Defrost Thermostat Kit
  • Michael from Encinitas, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
58 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leak at fill tube
Removed two screws that held cover plate. remove cover plate. Remove water hose, and clamp, by compressing clamp with pliers. Remove fill tube by pulling HARD, from back.

Replace fill tube, check to be sure that it entered ice maker properly. Replace hose and clamp.
Replace cover and screws.
Parts Used:
Speed Clamp Clip Plastic Tube Insert Refrigerator Ice Maker Fill Tube
  • Richard from Yarmouth, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
59 of 74 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
getting "black plastic" pieces on ice
I didn't know what the plastic was - just that it was unappetizing. Reading other posts, it must have been the teflon coating. The refrigerator is 13 years old and reading other posts, I guess I'm lucky it lasted that long.

My boyfriend did the repair and here is his story:

The first ice maker we received was cracked on one corner. Not knowing how it got that way, I was concerned that there might be additional internal damage and that the unit wouldn’t work properly. Part Select was contacted and a replacement unit was sent with no difficulty.
As other reviewers have said, the replacement was quite easy, taking less than half an hour. The only tools I needed were a screwdriver and a nut driver. To begin, unplug the refrigerator and turn off the water supply to the ice maker. Loosen, but do not remove, the two top attachment screws. Then remove the bottom screw. Lift the unit up off the top screws and remove the water inlet hose at the top right. It’s probably a good idea to have a container handy to catch the small amount of water that comes out, but you’ll need a third hand for this.
The electrical wiring harness is very short and may be tricky to disconnect. On my refrigerator there is a round vinyl connector that plugs into a receptacle on the back wall of the freezer compartment directly behind the ice maker. This was removed with no difficulty (accidently, actually). Once the unit is out of the refrigerator you can remove the connector from the ice maker by using a screwdriver to depress the latch tab that is visible in a window in the unit housing. When installing the connector in the new unit make sure it is fully seated. Next, reconnect the round vinyl connector to the receptacle on the back wall of the freezer compartment. This was the worst part of the whole procedure. You have to support the unit close to the back of the freezer (due to the short harness) with one hand while inserting the connector with the other. This requires both arms in a confined space. The first time I did it I apparently didn’t get a good electrical connection on one end of the harness, and it didn’t work. Because the connectors are directly behind the ice maker I had to remove the unit and re-install it, but it was much quicker the second time, less than 10 minutes.
Once the connectors are in place put the water inlet hose into the opening at the top right. You may need to re-use the retaining clip from the old unit for this. Slide the two top mounting ears down between the screw heads and the back wall of the freezer compartment and tighten the screws. Then install the bottom screw. Plug in the refrigerator, turn on the water and make yourself a frosty beverage.
All in all, a relatively quick and painless procedure.

Another note - we kept saying "is there ice yet"? I think the metal bar that controls the ice maker needed to be raised and lowered a few times before it would work properly as it seemed to raise 1/2 way but the ice would not drop so I put it down and it worked its way up. Had to do it a couple of times over a 4 hour span but once going, it is working like a champ.
Parts Used:
Replacement Ice Maker
  • Kathy D from Waterford, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
53 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
easy and quick
unscrewed to removed old and screwed in new
Parts Used:
Refrigerator Water Filter
  • alvin from irmo, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
87 of 163 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator had been working and still had lights and a running fan, but no cooling, everything had defrosted.
I didn't do it, my husband did. He removed the back panel and used an ohm meter to check the compressor and found that that was working so he decided to replace the overload relay and capacitator. He has an hour lunch and since the parts were in he decided to change it during his lunch hour. The minute he had them replaced....voila!! Cold again! We had a different fridge that had the same problem, but we thought it would be too expensive to fix so we junked it......wish we would have tried this!!! So proud of the hubby!
Parts Used:
Run Capacitor Overload Relay Combination
  • Teresa from Baraboo, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
48 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
while closing the door, the light switch fouled, resulting in the switch breaking
I used a flat screwdriver and released the lock tab on the bottom of the light switch, and pried the switch out, being careful to not damage the plastic around the mounting place of the switch, unplugged wiring from old switch, plugged in the new one and pushed the new switch into place. Job finished light switch now working.
Parts Used:
Door Switch
  • Kevin from Beckley, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
59 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker was dumping water into ice bin and the ice maker shut off arm broke its rear mount
First I removed the 14.3 tons of freezer contents, closed the water valve, shut off the juice, and removed the freezer bins, the freezer door and the three screws that held the element in place. After bringing in 397 hand tools from my garage inventory, I loosened the unit and, after extensive evaluation, I finally disconnected the wiring connector from its freezer rear wall connector counterpart. You ain't gonna believe the rest of my story--of total ineptitude by an experienced fix-it-yourself dummy.

I searched the internet for a replacement ice maker and found it at partselect.com. I called Sears to ask if I could add my refrigerator to my existing appliance repair account. Sears said sure--it would cost me only one arm, three toes and one grandchild. I abruptly declined their magnanimous offer—I don’t give up my arms and toes so easily.

I visited the local Maytag repair parts and service retailer, who advised they didn't do parts anymore. Expecting their repair price would be greater than Sears, I resorted to partselect.com. I called them to be assured what I was buying was not mistakenly a 747 Landing Gear. On the afternoon (West Coast) of 4/28/10, I ordered (via internet) one PS21215123 Ice Maker Assy. Much to my pleasant surprise, it arrived via FedEX on 4/30/10 (no freight charges to me).

My repair/replacement efforts were hampered by the effects of my right rotator cuff surgery a few months before and major left wrist surgery two months ago to remove fractured bones and torn ligaments.

Undaunted by my physical handicaps, I forged forward. After re-installing the unit, I turned the water supply and electricity back on. It was graveyard dead. I wisely then bought two bags of ice as an interim solution to the severe needs of my wife and me for our daily chilled evening cocktails. I removed the unit, checked it out and re-installed it. I bought two more bags of ice. All the while, I turned the water and electricity off and on as required by reasonable safety standards. High tediousness!

Several more home maintenance tasks then arose for Sergeant Super Fixer, but I returned to the ice maker problem on 4/8/10. Last chance--remove the device and insure there was no frozen ice in the inlet tube--or call the local partsless repairman. No ice found, but I did learn the wiring connector to the unit was awry--no contact! While explaining that to my wife, I realized the two upper mounting screws were intended to be partially installed into the freezer wall to accommodate the unit's slotted mounting holes! Then, tighten the screws. Oh my God! During my 143 installations and removals, I had installed those screws blindly--using the (handicapped) skills of my right and left hands without any benefit of direct eyesight.

I returned to my challenging project this morning (4/9/10), fully utilizing all the expertise I had gained yesterday. Fifteen minutes of amusing effort! Turn on the juice! Turn on the water!Two hours later, ice cubes were dropping into the bin like rhinoceros bisquits in the jungle.

Hallelujah! I now am free for the next challenge!

HINT: Put a bed pillow (an old one, or your wife's) in the freezer compartment to soften the harshness of its cold metal on your back, if you use the "crawl in on your back" approach.
Parts Used:
Replacement Ice Maker
  • GORDON from CUPERTINO, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
51 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
crisper drawers were off center rail due to c.r fracture
removed old rail,lifted glass panel above and inserted new rail-voila!!done.
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • albert from quakertown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
42 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor clicking but not turning on
I just opened up the fridge back panel accessed the old relay/capacitor, pulled it out, replaced with the new one, snapped it back into place, tested it (compressor came on), replaced the back panel and went on my way. Really, really easy repair.
Parts Used:
Compressor Start Device and Capacitor
  • brice from irving, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
45 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling
Problem: My Maytag side by side door refrigerator just stopped cooling and has to discard all frozen items after I discovered being away for 3 days. First, I went to my computer and read some of the repair stories at Part Select “Need help with your repair?” and installation video guide.
1. I ordered the Refrigerator Adaptive Defrost Board (ADP) - followed the procedures how to disconnect and installed the new part. Unfortunately, it did not correct the problem and only warm is coming out.
2. I ordered the Defrost Heater Thermostat Assembly - removed the old and replaced with new assembly. Again, warm air coming out. Meanwhile, I kept on hearing “clicking sound every few second” not knowing where this coming from. Again, at Part Select, I read the story about it and I ordered the
Run Capacitor and the Overload/Relay with Capacitor. Soon as I opened the parts and tried to match it from the part at the back of the refrigerator and to the part from the compressor, I have discovered that they are not in compatible with the original parts from my Maytag Refrigerator and cannot be installed. And so I contacted (Email) Part Select customer service (Jeanette) if I could return the unused parts and had provided me the “Return address and the Reference Number”. This time, I gave Jeanette the Maytag Model and Serial numbers and asked where I could find this on my refrigerator and make the necessary repair and came back with the diagram and located #4 to the compressor. Ordered the correct part# PS2004058.
3. Upon receipt of the part above, I was puzzled, in the plastic container are four parts, included a plastic cover. I have not given up, I removed the original part encased in white plastic container pulled straight off the compressor and examined it closely. Before detaching all the wiring, I also noted before disconnecting from wire harness and read the Diagram/Instruction Sheet provided.
4. From the four new parts provided, installed the Overload Terminal, bottom part on Compressor with one terminal to the Blue wire. Connected White Jumper to the old harness. Lastly, I plugged the PTC Start Device (two terminals) above the Overload Terminal on the Compressor with the proper wiring as I previously noted and installed the electrical cover. “Plugged in the refrigerator to the power outlet”. To test the result, I left a glass of water inside the freezer and a bottle of wine into the refrigerator. The result - I checked after 2 hours, the water was frozen and a cool wine. “Little frustration included here, as I am not an electrician.” But now, I could say, I fixed it, and very proud of this accomplishment.
Thank You, PartSelect and to a great Customer Support!
Safety Note: Always make sure to unplugged the refrigerator (power off) prior doing the necessary repairs.
Rodolfo Julao/S. San Francisco, CA
Parts Used:
Compressor Start Device and Capacitor Run Capacitor
  • Rodolfo from South San Francisco, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
39 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Parts Used:
Refrigerator Door Switch
  • James Richard from St. Cloud, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
44 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Parts Used:
Condenser Fan Motor Kit
  • robert from nashotah, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ARB2259CW