Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
The repair story webpage has some problems. I want to rate it "very helpful" but it showed "not helpful". I am pleased with the order service. It was very hard to find the parts on the web. There are a couple of web sites but only partselect has it in inventory. I ordered it, and it came in within 5 days. Excellent service. Will continue to order parts from this site in the future.
Repair man that looked at it said it was the thermostat and that he would order the part. Waited two weeks with no word, so I ordered the part on line, got it the next day and installed it. The only hard part of the installation was getting to the three screws (located vertically in top of refrigerator section) to remove them. Simple three wire clip on changed unit. Total time took about 5 minutes. Refrigerator started cooling when plugged back in. Unfortunately, cooling again stopped within a day, so the original problem was more extensive than just the thermostat (so much for the service call diagnosis). Thoroughly pleased with part ordering, would do it again.
The old motor has built in wire harness. The new motor has connectors on it.
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud. Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Unplug pwr cord ..then chk voltage on refrigerator...go inside refrigerator to upper unit where light is and lower unit dwn bye removing the screw then look for thermostat it's right inside ..remove to 3 wires then install new thermostat the same way....plug unit in to power rotate thermostat cooling setting and listen for compressor to tune on. If all goes well the refrigerator should cycle. ....if not change out control board. Good luck and have fun.
a rumbling noise was comming from the back of the fridge
I unplugged the appliance removed the back cover exposing the fan motor.Unplugged the wiring harness from the motor assembly.unbolted the fan motor mounting bracket,and removed. Next I unbolted the fan and motor assembly from the mounting bracket.( I pulled the whole bracket out so it would be easier to reinstall the motor and fan assembly,then reinstalled the bracket with the motor and fan already installed) I installed the bracket assembly with the motor and fan back to its location,plugged the wiring harnessback to the motor. replaced the bask pannel ,and plugged the 110 back in the wall socket
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Remove the cover off of the compressor connection box,,,pull the old start-device,replace it with the new one,and there it is running just fine. The amps droped to normal and the compressor is not over heating any more.Nothing to it. 15 to 20 min. Time to do the repairs
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Removed the cardboard baking on back. Unplugged the fan. Used 1/4 socket and removed the 3 nuts. Removed the fan. It is tight quarters. Take your time and the job will go fast.