refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Parts Used:
Condenser Fan Motor Kit
  • David from Granada Hills, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken handle
Removed old handle. Cleaned area. Installed new handle. Remember to save small cover at bottom of old handle.
Parts Used:
Door Handle
  • Aaron from Milan, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch broke off
We looked up the problem online with the model number of the refrigerator. We ordered the part and followed the video installation that was sent with the order and was found online prior to purchasing
Parts Used:
Refrigerator Door Switch
  • Kathy from TEMECULA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch lever broke
Unplug refrigerator.
Pry switch out with putty knife
Remove two wires from switch
Attach wires to new switch
Push new switch into slot
Parts Used:
Refrigerator Door Switch
  • Stephen from LOVELAND, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old seal was broken and leaking causing the freezer to ice up.
The repair was straight forward and was not hard. You do almost need 3 hands as the reinstallation of the inner door panel can be awkward. The only issue that I have is that the new seal has a poor fit. While it was received folded over on itself, this was not the problem. The seal does not expand enough on one side to fully seal the door. It also has a very weak magnet. If the magnet was stronger, then maybe it would seal better. It does still leak to some extent. The seal that was removed had a stronger magnet that the new one does. I would include a photo, but this system does not allow me to add attachments. Overall, I'm pleased with the time that it took to get the gasket, and the ease of replacement, but am not satisfied with the quality of the sealing or the strength of the magnet that holds the door closed. I would rate replace as 8 out of 10, and part quality and how it works as a 2 on a scale of 10.
Parts Used:
Freezer Door Gasket
  • James from WILMINGTON, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rocker on switch broke off
Eased the putty knife under the edge of the switch housing and pried it off. Pulled two wires off the old terminals and hooked them onto the new one and reinstalled into the refrigerator body.
Parts Used:
Refrigerator Door Switch
  • David Barnes from ROSWELL, NM
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fridge was running constantly. O
Once I removed the contents of the freezer I found ice on the inside back panel Removing the panel I found ice on the cooling coils and the defrost thermostat was bulged out where the wires were attached.I removed the panel with the nutdriver as shown in the video. I removed the ice maker connection and removed the panel from the freezer section. I then had to manually defrost the area with a heat gun. The ice had actually covered the Defrost Thermostat - which was bulging where the wires were attached.. The defrosting took the majority of the repair time - the actual Defrost Thermostat replacement only took about 20 minutes once I could get to it. I spliced the wire with a crimping tool as discussed in the video. Once all was defrosted I reversed the operation.Overall, a very simple part change out. The video was extremely helpful - if nothing else to mentally prepare me for the task.
Parts Used:
Bimetal Defrost Thermostat
  • Edward from BILLERICA, MA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Parts Used:
Condenser Fan Motor Kit
  • Kevin from COVINGTON, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light did not work on the refrigerator side
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what is inside the refer!
Parts Used:
Refrigerator Door Switch
  • David from GROVESPRING, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The plastic cover on the old hadle broke off.
It was very simple. Pulled the little cover off of the bottom screw and removed it along with the 2 top screws. Then just do the reverse to install the new handle.
Parts Used:
Freezer Door Handle
  • Walter from Green Valley, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
grille toe plate broken
I removed the old grille toe plate and snapped the new one in it's place.
Parts Used:
DISCONTINUED
  • Barbara from Shelton, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken handle
After popping off the lower cover all I needed was a screwdriver to remove both the upper 2 screws and the lower screw. The new handle was attached in seconds and it matches great.
Parts Used:
Refrigerator Door Handle
  • Debbie from Salisbury, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Circulation fan was not running
I have a side by side Amana fridge about 12 years old. One day I noticed everything was not cold anymore. I checked the temp with my infrared thermometer and it was about 70 in the top of the fridge, 40-50 in the bottom, and freezer was the same! So after pulling out the two baskets in the bottom of the freezer and the side rails that hold the baskets, I used a 1/4 nut driver to remove the back lower panel. After looking at the electrical schematic on the back of the fridge, I jumpered around the defrost thermostat, a little cylinder with two wires coming out of it. Bingo, the fan turned on. Well after a few days of running fine with it jumpered my new one arrived. I never really tested my old one with a meter so I did that and it tested fine, so I plugged the old one back in and it worked fine for a few days. Then one day I noticed that fan wasn't running again so I just put the new one in. I had to cut one of the connectors off as it was female instead of male and crimp cap it together, but besides that it went fine. So after connecting it I noticed the fan motor was buzzing but not spinning. I wiggled wires around and determined the connector going into the fan motor had to be a certain way to make the connection. I unplugged it, it wasn't corroded or anything but if pulled down on, it would not make connection. So pulling up on the connector proved that it would make good connection, so a ziptie keeping the wires tight in the up direction proved to be the solution. I'm pretty sure my old defrost thermostat was not the problem. So that's my story. Hope it helped.
Parts Used:
Bimetal Defrost Thermostat
  • Ryan from Otsego, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Referigerator section was warm, freezer cold
I removed the back cover in the freezer section by removing six screws. The entire coil, the thermostat and the lines were all iced over. I used a hairdryer to defrost everything. I removed the thermostat by uncoupling the connectors and unclipping it from the coil tubing. I found the thermostat was bulging and deformed. I jumped out the thermostat using an insulated clip lead. I taped it so it would not short to anything. I plugged the unit in, turned the unit to "1" and advanced the defrost timer to defrost. I could hear the water hissing on the coil. I ordered the thermostat. It arrived in 3 days. The new one had a different terminal. I cut off the matching one from the old part and used a scotch-lok to make the connection to the new part. I slapped it in, dressed the wires and replaced the cover. I noticed that when I advanced the timer after replacing the thermostat, it did not immediately come on. The thermostat has an operating temperature window. I checked it several days later and found no frost. Everything works great.
Parts Used:
Bimetal Defrost Thermostat
  • Thomas from Hicksville, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warm
First of all let me say I can't believe I fixed it! And I can thank this website for it, they also had my part at my front door in less than 24 hours. I am so amazed! I am a stay at home Mom, and because my husband is always off with the military I knew the job was up to me to fix. And because times are tough we certainly couldn't afford a repairman. After reading many stories here about the same problem I had, I diagnosed what was wrong with my refrigerator. The defrost thermostat was faulty. First thing to do was turn off the refrig and then unplug it. I then emptied the bottom freezer, used a screwdriver to remove back panel wall. Lo and behold the coils were covered with ice. I defrosted the freezer using a blow dryer, also had to empty the drip pan in the back. when it got full of water. ANd because there is no way to remove the drip pan, I actually got a small air hose from my son's old fish tank(clean one) and then siphoned the water into a pot, took all of 10 minutes! I then used needle nose pliers to remove the bad defrost thermostat from the refrig's wiring.The defrost thermostat which had a bulge in it so knew I was on the right path. I looked at the new defrost thermostat and they had different ends on it then the one I just removed, and I remember reading what another member did, and that was to cut off the connecting caps, strip the wires , use electrical tape to join them and use a crimping tool to place the old caps on to the new defrost thermostat .I then inserted the thermostat to the freezer's wiring. Hope that makes sense to everyone. WEll, everything is running great! Thank-You Part Select, you saved me lots of money!
Parts Used:
Bimetal Defrost Thermostat
  • Caren from Marlboro, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!