light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
I have a fridge in one of my rentals that was missing 2 crisper drawers
I ordered the crispers and they came the next day.I took them out of the box and had them installed in about 30 seconds.It doesn't get any easier than that.The lady on the phone was very helpful when I placed the order.The fact that they came the very next day was amazing to me.
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Ice buildup on the bottom of the freezer, water dripping into the refrigerator
After unplugging the refrigerator, I used a hairdryer to melt the ice sufficiently to be able to remove the freezer rear panel with a nutdriver. I also removed the ice-maker for easier access to the components behind the panel, using a nutdriver. Once the panel was removed I melted more ice at the bottom of the evaporator housing. After partially melting the ice in the drain tube, I poured hot water down the drain tube until it cleared, signaled by the sound of the water dripping into the drain pan. I next removed the clip-on Bimetal thermostat from the copper line going into the evaporator and snipped the two wires to remove it. I installed the replacement thermostat with crimp-style connectors and pull-tested them. I also replaced the timer board that is located below the freezer, below the top shelf, using a nutdriver. I replaced the circuit board as a precaution that the thermostat may not have caused the problem. I didn't change the heater inside the freezer as it checked out to have the same resistance as a new one. I tested the removed thermostat using a glass of ice water but it remained in the open condition, using an ohmmeter. (I later checked that thermostat after the freezer was running and it did close, and returned it to the open position by heating it under the hot water faucet. I suspect that it didn't work properly, or the timer control board was faulty). After re-installing the back panel and ice-maker and plugging the refrigerator into the power receptacle, it worked very well, and has done so since the repair.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
freezer constantly covered with ice not defrosting
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twenty minutes and Tim Allen has nothing on me. Mike Milne