Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
1. Turned off the cooling cycle and unplugged the refrigerator. 2. Removed all of the shelving and bottom basket. 3. Removed rear covering in the freezer section. 4. If frosted over, manually defrost coils with hairdryer. 5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat. 6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape. 7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location. 8. Replaced the rear cover and shelves. 9. Plugged in the refrigerator and set the cycle back to cooling. 10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Unplug fridge, tilt back against wall to provice clearance to install new assembly. Used self starting screws to install. Used cordless drill with nutdriver to install assembly. Time to complete job-5 minutes
After first ordering the wrong end part, I reordered the correct part and successfully attached the handle end and handle to the refrigerator door. The handle itself was too long, and I had to cut it down to the correct size. I am a realtor and provided the service to my buyer of the condo that was my listing. Thank goodness for your company and the ability to buy parts for an old model!
Refrigerator started frosting up and running all the time.I'd defrost it and it would frost up again in about a week.The timer seems to be work so I just guest it mite be the Defrost Thermostat.I removed the duck in the center and back panel in the freezer compartment defrosted it and switched Thermostats and replaced panel and duck, going to lower compartment of the refrigerator.So far it seems to be working a little more time while tell.
The refrigerator light would not work ...even after replacing the bulb.
I used a flat head screwdriver to pry open the front of the socket as I pushed the socket toward the freezer side. I unplugged the two wires connected to the socket then re-connected the two wires to the new socket and popped the new socket back in. I then put a new light bulb in and we had light again in the fridge.