Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Parts Used:
Refrigerator Door Switch
  • James Richard from St. Cloud, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
44 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Parts Used:
Condenser Fan Motor Kit
  • robert from nashotah, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Nozzle was broken
Didn't know if part was replaced from the front or back of door. Removed back/inside first. Good excuse to clean mold found in places not normally seen. The only real problem was getting the face off the dispenser without breaking it. I now know it snaps off from the bottom. To replace one little nozzle you have to replace about 10' of tube. When I pulled the old tube out. I attached fishing line to it and used to fishing line to help feed the new tube through the door.
Parts Used:
Nozzle and Tube Kit
  • Robert from Tuckerton, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
34 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan motor was loud,sqeal,would not get cold
Very easy, hardest part was taking panels out of way. 20 min. to finish. After repair it works like new.About 20 years old.
Parts Used:
Evaporator Fan Motor Kit
  • Thomas from Monsey, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
35 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaked on floor when water dispenser was used.
1. Turn off water supply to refrigerator.
2. Unscrew water nozzle from dispenser.
3. Remove grill on bottom front of refrigerator.
4. Unscrew tubing at the left side of the union.
5. Unclip tubing from the refrigerator frame.
6. Pull tubing out of the dispenser about 6 inches.
7. Cut off nozzle with scissors.
8. Insert 1/4" diameter x 1" long molly bolt about halfway into end of tubing where it was cut.
9. Insert the remainder of the molly bolt into the end of the new tubing.
10. Pull the old tubing through the bottom of the door.
11. When the new tubing is pulled all the way through the door disconnect from the old tubing. Remove molly bolt if it is in the new tubing.
12. Remove the ferrel from the old tubing and use to attach new tubing to the union.
13. Connect the water nozzle to the dispenser.
14. Insert new tubing into the clips on the refrigerator frame.
15. Re-install grill.
16. Turn on water.
Parts Used:
Nozzle and Tube Kit
  • Dave from Danville, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
28 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
Parts Used:
Refrigerator Door Switch
  • David from Albany, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
34 of 52 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
motor coupling weld broken
Removed four screws from ice maker motor/light support.Then unplugged electrical plug from side of freezer.Used two slip joint pliers to remove coupler from motor shaft. installed new coupler to shaft hand tight as will tighten as motor is run.Then reversed tear down order.
Ice dispenser works better than when we first got the refrigerator
Parts Used:
Ice Dispenser Motor Coupling
  • HAROLD from SPRING HOPE, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Parts Used:
Condenser Fan Motor Kit
  • Janet from Hillsboro, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Parts Used:
Condenser Fan Motor Kit
  • Florentino from Windsor Locks, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Parts Used:
Condenser Fan Motor Kit
  • W from Nellysford, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Just a trickle of water to icemaker and water dispenser
Turned refrig off, pulled it out for access to the valve, unplugged refrig and turned off water supply to the outlet valve. I made the installation a bit more difficult by over tightening the supply line connection which ruined the brass compression washer. I replaced it with a plastic compression washer which is probably better since the supply line is plastic. The electrical connections were very simple. I was just guessing the old outlet valve was bad since I had checked the filter. After replacing the valve, the ice maker and water dispenser work like new on a 17 year old refrigeration. Also, I was very pleased with fast processing and delivery of the order.
Parts Used:
Dual Outlet Valve Kit
  • Bill from Hot Springs Village, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
in door water dispenser tube broken off 1.5 inches from end
shut off water supply behind fridge then released trapped water pressure in the line at the dispenser. Locked off dispenser controls (push button switch). Removed nozzle retaining screw and pulled out nozzle approx. 3 in. to cut off tubing at black pipe so as to use the old pipe as a guide/pull (fish) for the new pipe by joining the end of the new nozzle to the cut and of the old pipe with electrical tape.Then pulled the old pipe from bottom of fridge while simultaneously feeding/pushing new pipe from top. I had to remove lower grate on fridge to access the pipe on bottom. Remaining coupling connection on bottom was done by hand to avoid stripping plastic coupling.
Parts Used:
Nozzle and Tube Kit
  • haig from La Quinta, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Wrench set
23 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not keep running.I had to tap the cold control with the blunt end of a knife
first I unpluged the refrigerator, then removed the nob for the cold control thermostat. then I removed the plastic cover, and removed the lightbulb. this revealed the metal plate that holds the cold control. four screws held this in place.once theplate was loose I unpluged the three wires that plug into the cold control, and removed the two srews that held it in place. then I remved the cold control thermostat, replaced it with the new one hooked up the wires, replaced the metal plate and lightbulb,and the plastic cover. plugged the refrigerator back in, and turned it back on works great now. I hope this will help others to make their repairs easier thanks, gary
Parts Used:
Cold Control Thermostat
  • gary from fort bragg, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Parts Used:
Condenser Fan Motor Kit
  • Bob from Hesston, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic Water Spout Broke Off
Turn off water supply line fridge. Removing front panel is a must to allow acces to spout and water line. Be careful not to crack front panel $90, it snaps in from the botton, slide a stiff putty knife along bottom edge and gently pry outward to remove. Remove 2 screws that hold spout in place, then cut water line right behind spout. The tricky part is fishing water line down through door. You need to splice new line to old with double sided screw or something with threads that will prevent the lines from pulling apart, then pull water line from bottom of door by hinge, very tight when pulling through hinge opening. You will need to remove vented dust cover at botton of doors to acces the water line. The line has a threaded coupling so unscrew and drain water then cut new line to length. There is a small metal insert in old line that needs to be removed and inserted into new line before attaching coupler. I could perform this in half the time now that I have done it once.
Parts Used:
Nozzle and Tube Kit
  • Michael from Colorado Springs, CO
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1068536712
16 - 30 of 644