Models > 1068221660 > Instructions

1068221660 Kenmore Freezer - Instructions

All Instructions for the 1068221660
1 - 15 of 102
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The door would not close properly. The CAM had broken.
The repair was very simple.

1. Remove the food from the door shelves.

2.Remove the door by first removing the three screws holding the hinge at the top of the refrigerator.

3. Lift door off of the bottom hinge.

4.Replace bottom CAM on bottom hinge (one screw)

5. Replace top CAM and shim on door (one screw)

6. I put a little grease on the cam to make it slide better.

7. Place door on bottom hinge. Remount top hinge.

8. Done and works better than new.
Parts Used:
Door Closing Cam Kit
  • Thomas from San Clemente, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
143 of 147 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Would Not Go On In The Refrigerator
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Parts Used:
Light Socket Kit
  • DANIEL from MINNEAPOLIS, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
61 of 77 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Main Door wouldn't self-close
After removing all the food items from the door, I popped the plastic cover off of the hinge assembly located on the top of the door. With a fine point Sharpie pen , I marked the outline of around the hinge assembly so I could return it to original position. I then loosened each of the 3 bolts holding the hinge on just enough to allow me to clear the pin of the hinge out of the hole in the door. Once the top was free of the hinge, I lifted the door off of the bottom hinge/pin assembly. My cam parts on the bottom hinge and door were either broken and/or partially missing. I removed the broken and worn pieces by removing each of the screws holding the top and bottom (of the bottom hinge assembly) cam pieces and installed the new ones using same screws. I then reversed the steps and slid the bottom of the door back onto the bottom hinge assembly and then lifted the top hinge enough to allow the hinge pin to slid back into the hole on top of the door. Positioned the hinge so it matched the outline and tightened the 3 bolts. I checked the closing and made a slight adjustment to door as one of the shelves was hitting the interior as it tried to close. I did this by loosening the 3 bolts and pushing the door up and to the right (this door was on the right side of refrigerator). Tightened the bolts and reinstalled the hinge cover.
Pretty easy. My door cams were a little different so I didn't use all the parts in the kit. My shims were metal and did not move when I replace the cams so I didn't use anything in this repair except the 2 lower cam parts. I also put some grease/vaseline on the cams to lubricate them.
I figure the plastic cams just wore out over the years and all the heavy junk we put in the door shelves. I lived with this problem about 2 years before it donned on me that it was probably just a plastic piece or two that was broken or worn out.
Parts Used:
Door Closing Cam Kit
  • Gary from Huntington, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
43 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door not swinging freely and not closing automatically
replaced lower door closing cams and shim and cleanded and lubricated top and bottom hinge. Took about 30 minutes. Hardest part was unloading the door and finding a place to put all the bottles and stuff. Door works just fine now.
Parts Used:
Door Closer Shim Door Closing Cam Kit Door Cam - Black
  • Harold from Sun City, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator door made a terrible bang every time it was opened.
The hardest part was unloading all the food from the refridgerator door! Once done, pry shroud off top door hinge, remove 3 screws and hinge plate. Lift door off bottom hinge. Remove one screw from bottom of door, remove and discard old lifter cam and spacer. Clean up a bit. Install new spacer and lifter cam. Tighten new screw firmly. Replace the lifter cam and spacer on bottom hinge pin (affixed to refridgerator body) using the same method. Replacing the door is easiest if 2 people do it. One person to lift and steady the door, the other has to lie on the floor and guide the door onto the hinge pin. Replace top hinge plate and screws. Snap shroud back over top hinge plate. Replace food in refridgerator. Close door. Done!
Parts Used:
Door Closing Cam Kit
  • Hank from Seattle, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator door was making a popping noise when opening and closing
Not being a handyman I found this job realtively easy.I took most of stuff off fridge door, to make door easier to handle. I then undid top hinge door screws, 3 of them, lifted door out., replaced 2 cams.When putting door back on fridge, you have to make sure door is in exact position and top hinge is lined up exactly, or door will continue to pop a little.It took me a couple of times to get top hinge lined up exactly.
Parts Used:
Door Closing Cam Kit
  • Vincent D from Blackwood, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
Parts Used:
Door Cam - Black
  • Michael from Lewisville, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not stay closed
Removed the top plastic hinge cover, remove (2) bolts from top hinge. Lifted door up and off of lower hinge, removed both halves of door cam, replaced cam halves and re-installed door. Super easy and effective. Door now opens and closes (stays closed) properly.
Parts Used:
Door Closing Cam Kit
  • David from Chagrin falls, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
Light Socket Kit
  • David from Roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
had to push door closed
lifted door 1/2 inch and put blocks of wood under the door and replaced the lower hindge cam.
Parts Used:
Door Closing Cam Kit
  • peter from portsmouth, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud thud when door opened.
Remove all items from the door shelves. Removed the top hinge cover and removed hinge mounting screws. Lifted door off bottom hinge and laid it on its side. I then replaced bottom hinge cam by removing (1) cap screw. Very simple job.
Parts Used:
Door Closing Cam Kit
  • Floyd from Rushville, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Parts Used:
Light Bulb - 40W
  • Carl from RIVERSIDE, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Freezer Door Cams
1. Put pieces of wood under door to support it.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
Parts Used:
Door Cam - Black
  • Dennis from Corona, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1068221660
1 - 15 of 102