3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Parts Used:
Defrost Timer
  • Gerald from Orangeburg, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud thud when door opened.
Remove all items from the door shelves. Removed the top hinge cover and removed hinge mounting screws. Lifted door off bottom hinge and laid it on its side. I then replaced bottom hinge cam by removing (1) cap screw. Very simple job.
Parts Used:
Door Closing Cam Kit
  • Floyd from Rushville, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frig stopped running and everything ruined
The frig was already empty....removed the plastic control knobs and loosened the hex head screws to remove the cover . The wires were the same at each contact point, so, it took about 15 minuets to adjust the control knob to match the old one and reinstall the thermostat and place the cover...The other 15 minuets I spent finding my wife to show her the frig was back to work...Just a walk in the park...
Parts Used:
Cold Control Thermostat
  • allen from Dickson, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Parts Used:
Light Bulb - 40W
  • Carl from RIVERSIDE, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Parts Used:
Ice Maker Water Fill Tube Kit
  • Matthew from Phoenix, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Parts Used:
Ice Maker Water Fill Tube Kit
  • Alan from Chino, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
Light Socket Kit
  • Elyse from Skokie, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door closing cam was broken
the process was pretty straight forward though the part came without instructions. We were able to replace the part improperly with ease. however, we were not able to get the pieces aligned properly for a long time. We ended up taking the door off many times to try to realign the pieces. After many hours I finally unscrewed the bottom cam while the door was in place. The piece popped into place and all was fixed. Had the part come with directions telling us to do this we would have replaced the cam within 15 minutes!
Parts Used:
Door Closing Cam Kit
  • lizie from nantucket, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Freezer Door Cams
1. Put pieces of wood under door to support it.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
Parts Used:
Door Cam - Black
  • Dennis from Corona, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Installing old ice maker in new freezer
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.
Parts Used:
Ice Maker Water Fill Tube Kit
  • Harry from Ten Mile, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
badly worn cam
Exactly as the demo instructed. It was very detail friendly and was very easy to follow.
Parts Used:
Door Closing Cam Kit
  • harry from KINGSPORT, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?