Noisy freezer evaporator fan motor
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan motor is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
would shut off and not restart without tapping on knob
replaced the cold control thermostat . The new one was oriented 90 degrees off (on the bracket mount) so I had to turn it (in the bracket) to line up better with the wire connections and temp sensor tube. The power wires can be connected to either terminal however, and I suppose you could leave it as is if your wires can reach. Turning it will make the knob off 90 deg. off from original markings (off to coldest) but I simply remarked the position with a marker. (make sure you connect all terminals before mounting the bracket, it's much easier that way. .Note: this was a 40+ year old Sears "Coldspot" refridg. and it works like a dream since I changed out this original cold control. Love these old mechanical appliances that are much more reliable than the new brokered ones. Glad whirlpool has made many parts interchangeable through many years...kudos to them
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
I replaced the defrost relay folling instructions I read on the internet--and it still didn't work--So I replaced the compressor start relay which was easier than the defrost relay--it worked and the fridg is working good.
Refrigerator coils froze up and 5 weeks later it got stuck in defrost.
The parts were reasonably priced, shipped promptly and received in a couple of days. I reviewed a YouTube video before starting that was beneficial. Huge savings over retail repair service. A+ replacement parts house and I would highly recommend.
Remove bottom of freezer by sliding out the gaskets on each side.
Remove back of freezer. 6 screws.
Remove fan cover. 4 screws.
Remove fan. 3 wires to disconnect. 2 screws to take out.
Install the fan. Connect the 3 wires. Fastened with 2 screws. Put fan cover back on. 4 screws. Put back of freezer back on. 6 screws. Put bottom of freezer back in. Slide gaskets in on each side.
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
My fridge did not have icemaker add on. The evap fan is in the freezer behind the back panel. Empty the freezer section (into a cooler) and turn the fridge off. Remove all the shelves in freezer section. Remove the shelf support tabs by lifting them up. use phillips head screwdiver to remove back panel in freezer section. Use nut driver to remove fan shroud. Remove old fan and save the mounting arms. Install mounting arms on new fan and install fan. Install shroud, back panel, shelf mounts and shelves. Thats it!