Wasn't making ice
Took off door to ice maker. Unscrewed 1 nut. Slid out unit. Unplugged electrical connector. Unsrewed 3 nuts from bottom of old unit & attached mounting bracket to new unit. Reconnected electric connector. Slid back in. Put screw back in. Put icemaker door back on. Turned icemaker on. Ice in 20 minutes!
Parts Used:
Replacement Ice Maker
  • Albert from Centereach, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old motor was not resetting back to proper position halting ice production.
Removed the three motor screws pulled off old motor put new motor in place replaced screws and re-installed. It was producing ice three hours later. I originally tried to obtian these parts directly from Whirlpool in which twice they shipped me the wrong parts. Finally gave up on them and entered the whilrpool part number which crossreferenced to new part number which was correct the first try. Thank you!
Parts Used:
Icemaker Motor Kit
  • Kevin from Spring, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Parts Used:
Defrost Timer
  • David from Arnold, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit refrigerating
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Parts Used:
Defrost Timer
  • William from Hudson, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking water inlet valve
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I spent most of my time trying to fit the valve into the old space.

Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.

Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished

Everything works just fine !
Parts Used:
Refrigerator Single Water Inlet Valve
  • Steven S. from Kerrville, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker stopped working
First I unplugged the unit, then I popped off the cover to the icemaker electronics. Removed 4 screws, pulled out the broken electronic panel, and replaced with the new one. Returned the screws and cover. The next moring the ice bin was full.

This must have saved me $300, and the inconvernience of waiting around for the repair man. He would have made two trips since he would never have had this part with him.
Parts Used:
Icemaker Motor Kit Touch-Up Paint - White
  • Duncan from Larchmont, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door handle broke off
It would have been nice to know that screws were not included and/or show were screws could be purchased. Thank goodness I was able to reuse the top 2 and had an extra screw in my tool bag that fit the bottom, because the existing screw had been super glued into bottom part of handle.
Parts Used:
Door Handle - White
  • Debbie from Eagle, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Parts Used:
Defrost Timer
  • Thomas from Pottstown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator ran constantly and never got cold!
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever and I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Parts Used:
Defrost Timer Refrigerator Door Switch
  • Brandon from Fort Wayne, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer was not "working " ,ice machine not working.
Removing the panels inside the freezer section was the most difficult ,because it is narrow,hard to fit your body inside compartment, in order to cut wires and to splice Bi-metal Defrost Thermostat wires (2 ) Watch the videos on the web site so you know where to start. First time I ever "repaired " a large appliance, saved me over $ 600.00 (that's what the people I bought the Refrigerator from wanted to charge me.) My parts cost 65.00 !!!!! My younger brother turned me onto the web site... , I'll be returning to the site and telling my friends about it. It's a total "rip off" what service organizations charge the general public these days from Car Dealer ships to the stores we purchase our appliances from. !!! Glad I still have my health and faculties to repair the essentials we have around our homes. !!!!
Parts Used:
Capacitor Bi-Metal Defrost Thermostat
  • Guy from MUNSTER, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to the ice maker
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I sent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.

Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Parts Used:
Replacement Ice Maker
  • Ron from Ferndale, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
Parts Used:
Defrost Timer
  • Maxine from Birmingham, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
THERMOSTAT
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Parts Used:
Bi-Metal Defrost Thermostat
  • dominique from COMPTON, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!