2 of 5 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsScrew drivers
CustomerVera from Alexandria VA
Noisy evap fan motor
Could not haven been easier. Simply unplug fridge, remove air duct mounted on rear panel, release panel itself, pull fan blade off, disconnect grounding wire, detach fan motor bracket, disconnect wire harness to release fan motor, install new fan motor and reconnect, secure with bracket, reconnect grounding wire, reposition fan blade onto motor shaft, reinstall rear panel and secure screws. Remount air duct and plug appliance back in. VOILA. All done in less than 15 minutes!!!
|