10 of 11 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsNutdriver
CustomerMarcus from SLC UT
My fridge and freezer were not getting cold enough.
The Fridge and freezer were not very cold except for in the very back of the freezer (where the coils are). So I opened up the back of the freezer by first removing the dome light cover and removing all the visible screws. I then lifted up and pulled out the vent in the center of the back panel and removed the two remaining screws on the back panel. At that point I removed the back panel exposing the coils and fan. I saw that the fan was not spinning so I used a screw driver to manually turn the defrost timer found on the top of the inside of the fridge. Once I had turned the defrost timer once complete rotation, and the fan didn't turn on, I was pretty sure that it was the fan. I still wasn't sure that the fan was the only problem, but I couldnt see anything else that wasn't working properly. I decided to take a chance and order the fan motor (not the entire assembly. it is easy to replace the moter only leaving the original fan blades and housing). Once I got the part, I unplugged the old fan motor, put in the new fan motor, and pugged it in and it started spinning right away. I put everything back together the same way I took it apart and it has worked great ever since.
|
5 of 6 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsNutdriver, Screw drivers, Socket set
CustomerTony from Los Angeles CA
Fan was making annoying noise and rubbing against the frame of opening.
Removed old fan and replaced the fan with new one. 2 years ago, the refrigerator was under warranty and tech replaced the fan but I found that the fan was not the original spec fan. Apparently, the fan that the tech replaced did not fit opening.
Now, my refrigerator works no problem. Save a ton of $$$ by doing it myself. Do not have to buy a new fridge and this one works perfect.
|
4 of 5 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsNutdriver
Customered from show low AZ
Freezer cold refrig warm
LOCATED FAN IN FREEZER COMPARTMENT REMOVED COVERS AND 8 SCREWS UNPLUGGED FAN AND REPLACED MOTOR REALLY EASY... RESET TEMP CONTROLS WORKS GREAT!!!!!!!
|
2 of 5 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsScrew drivers
CustomerVera from Alexandria VA
Noisy evap fan motor
Could not haven been easier. Simply unplug fridge, remove air duct mounted on rear panel, release panel itself, pull fan blade off, disconnect grounding wire, detach fan motor bracket, disconnect wire harness to release fan motor, install new fan motor and reconnect, secure with bracket, reconnect grounding wire, reposition fan blade onto motor shaft, reinstall rear panel and secure screws. Remount air duct and plug appliance back in. VOILA. All done in less than 15 minutes!!!
|