Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Leaking And Making Stalactites
Had to defrost the freezer to melt off all the ice before servicing. Once that was done the icemaker replacement only took about 15-30 minutes to complete. The new icemaker came with many accessories and adaptors that were not needed and the instructions were based on replacing an older model and not really clear for my model. They mentioned not being able to use the new stripper but it was exactly the same as the old one so I left the new one in place. All in all it was easy and did the job.
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
water over filling ice tray and leaking into ice tray and freezing
Followed the directions on the web site and did everything that was instructed to do and had no problems with installing the new dual water Valve. Has been in now for a week and no more over filling or freezing water in the storage box. Lots of clean ice, now!
A few small ice cubes in an empty try on return from vacation
Look at various pertenant DYI articles and videos on the internet. Replaced water filter with bypass plug. Checked water flow to icemaker water solenoid. Ran icemaker diagnostic test which failed. Ordered replacement. On receipt of replacement, began replacement work. To wit: Pulled fiidge from wall and unplugged. (Not necessary to shut water off.) Removed small freezer basket. Unloaded main freezer basket, removed it then removed the freezer door. (A screw on each side bolts the door rail of the chassis slide to the freezer chassis slide.) Loosened screws on rear, top of partition between icemaker and small freezer basket. Pushed up on partition front and popped out U-bar supporting partition bottom being carefull not to bend it. Removed same. Removed screws from partition and set aside. Removed grilled "thingy" between rear of icemaker and partition. Now have access to icemaker screws. Loosened the screws, pushed up and out and carefully let it hang by it's connector. Fiddled with the connector locking tabs and finally got it loose. Compared old and new icemaker. Have to keep the old water funnel. The new wiring harness was stiff and the connector had a different orientation. Twisted both the wiring harness and connector to align connector while the icemaker hung by it's cable being careful not to let the icemaer slip and fall to the bottom. After much fiddling, got the connector inserted and locked. Set icemaker over the two screws, pulled it down and tightend the screws. Put the old funnel into the new unit being very careful to get it right the first time. Put grilled "thingy and the partition and U-bar back in, put door back on, put the ice cube bin back, freezer drawers bac and reloaded the frozen food, plugged fridge in. Done! Time to replace icemaker was about 20 minutes and another 2 hours to do the rest ofthe work. Still required only a nutdriver and phillips.
I watched the instructional video on this website and did everything that it said. There is no more leak when I use the in door water. Was as easy as it looks in the video and I am very happy!
Turn off water valve to the refigerator and disconnect line. Remove the cardboard backing and insulation. Remove old valve and cut lines close to the valve. Trim plastic on new valve as needed to fit (generic valve). Insert water lines into new valve. Install new valve. Connect water line and open valve. Replace cardboard backing and insulation.
unplug refrigerator. Remove Ice bin then remove the cover off the ice maker,(slides off from bottom then lift off top) no reason to remove ice maker completely. Remove center gear screw and remove main gear from Ejector blade. remove (3) screws holding the front plate. The motor and switches are attached to this plate from behind, do not remove the nut from the from the stud that adjusts the travel for the motor. The Motor and switches will come upt with the plate and the shut off arm will come out of a hole in the top right. Its ok just be careful when you put it back to get it in the hole. remove the old cam and replace it wint the new one and reassemble. Its a bit tricky to get all of the microswitches over the new cam just carefully wiggle the plate and cam and don't push too hard. once everything is lined up it should go back together and you can replace the screws and main gear :)
Video is a great but still need to read the instuctions because there are parts you may need on the old ice maker. Saved myself a bit of money by not having to call a repairman. The process was very simple. I am glad I did it myself. Thank you Parts Select!
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
First i removed two screws that holds the ice maker in, unplug the plug to the ice maker. I was able to remove the old one. Place the new one in screwed in the two screws and pluged in the plug and in just a little while i had ice again. I am a women, if i can do it any one can. I had a repair man tell me it was going to be $250.00 dollars to replace it. I got on line ordered the ice maker and had it in 4 days. Very fast shipping and easy to install. Tina Kearns Beaumont, Calif
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover